Natural Gas Conversion
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect
Reconnect the
Failure to follow these instructions can result in death or serious burns to children and adults.
1.Turn manual shutoff valve to the “closed” position.
2.Unplug range or disconnect power.
B
A
C
A. To range
B. Manual shutoff valve “closed” position
C. Gas supply line
To Convert Gas Pressure Regulator
1.Open broiler door and remove broiler pan. The gas pressure regulator is located in the back right hand corner of the broiler compartment.
A
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
NOTE: Do not remove the spring beneath the cap.
2.Remove the cap from the gas pressure regulator using a
A
A.Cap
3.Turn the cap over so that N or NAT is visible.
A
A. Cap
4.Reinstall the cap.
To Convert Surface Burners
1.Remove burner grate, burner caps and burners.
C
A
B
A. Burner cap
B.Burner
C.Center burner
2.Locate the Natural gas orifice spuds for top burners in the bag containing literature included with the range. Three Natural gas spuds are stamped “125,” one is stamped “132” and one “128.”
3.Remove the LP gas orifice spuds using a 7 mm combination wrench.
14