Whirlpool UXT4230AY Wiring Diagram, For non-vented recirculating installations, To replace filter

Models: UXT4236AY UXT4230AY LI3Z4C W10400322F

1 32
Download 32 pages 24.74 Kb
Page 14
Image 14

For non-vented (recirculating) installations:

The charcoal filter is not washable. It should last up to 6 months with normal use.

1.Replace metal grease filter with a charcoal filter. For information on ordering, see the “Accessories” section.

To replace filter:

1.Remove screw from the grease filter retainer.

2.Turn the grease filter retainer to release filter.

3.Reinstall the filter by placing the back edge in the channel at rear of hood. Push filter into place, turn the filter retainer to secure filter to range hood.

4.Replace screw in the grease filter retainer.

Replacing the Incandescent Light Bulb

Turn off the range hood and allow the light bulb to cool.

1.Disconnect power.

2.Squeeze the plastic lens cover and remove it from the hood.

A B

A. Light bulb socket

B. Lens cover

3.Screw light bulb into socket.

4.Replace lens cover by squeezing cover and inserting tabs into slots.

5.Reconnect power.

If new light does not operate, make sure the lamp is inserted correctly before calling service.

WIRING DIAGRAM

Motor Switch

Off - On

BK

RD

BK

RD

WH

NOTE: Speed 1 not used

Speed 2

Common

Speed 1

 

C25

 

 

 

BK

WH

RD

 

Motor Characteristics

 

Power Supply

 

120 VAC

 

Frequency

 

60 Hz

 

Amperage

 

1.2 ±10% A

BK

Wattage Rating

 

73 ±10% Watts

 

 

 

Motor Resistance

 

White - Red

 

17.1 ±10% Ohms

L

White - Black

 

13.6 ±10% Ohms

Lamp Switch

 

 

 

Off1

- Low 2- High

 

 

Lamp Switch

L

 

3

 

Operation

 

 

1 - 2

Off

 

 

1 - 3

Low

 

 

 

1 - L

High

 

 

 

 

RD

YL

Rectifier

 

 

 

 

Diode

 

 

 

BK

WH

Ground

Screw

WH

SE114A

NGND

14