For non-vented (recirculating) installations:
The charcoal filter is not washable. It should last up to 6 months with normal use.
1.Replace metal grease filter with a charcoal filter. For information on ordering, see the “Accessories” section.
To replace filter:
1.Remove screw from the grease filter retainer.
2.Turn the grease filter retainer to release filter.
3.Reinstall the filter by placing the back edge in the channel at rear of hood. Push filter into place, turn the filter retainer to secure filter to range hood.
4.Replace screw in the grease filter retainer.
Replacing the Incandescent Light Bulb
Turn off the range hood and allow the light bulb to cool.
1.Disconnect power.
2.Squeeze the plastic lens cover and remove it from the hood.
A B
A. Light bulb socket
B. Lens cover
3.Screw light bulb into socket.
4.Replace lens cover by squeezing cover and inserting tabs into slots.
5.Reconnect power.
If new light does not operate, make sure the lamp is inserted correctly before calling service.
WIRING DIAGRAM
Motor Switch
Off - On
BK
RD | BK |
RD | WH |
NOTE: Speed 1 not used
Speed 2 | Common | Speed 1 |
| C25 |
|
|
| |
BK | WH | RD |
| ||
Motor Characteristics |
| ||||
Power Supply |
| 120 VAC |
| ||
Frequency |
| 60 Hz |
| ||
Amperage |
| 1.2 ±10% A | BK | ||
Wattage Rating |
| 73 ±10% Watts | |||
|
| ||||
| Motor Resistance |
| |||
White - Red |
| 17.1 ±10% Ohms | L | ||
White - Black |
| 13.6 ±10% Ohms |
Lamp Switch |
|
|
| |||
Off1 | - Low 2- High |
|
| |||
Lamp Switch | ||||||
L |
| 3 |
| Operation | ||
|
| 1 - 2 | Off | |||
|
| 1 - 3 | Low |
| ||
|
| 1 - L | High | |||
|
|
|
| |||
RD | YL | Rectifier |
|
|
|
|
Diode |
|
|
|
BK
WH
Ground
Screw
WH | SE114A |
NGND
14