Whirlpool WPDH160XS InstallDehumidifier-ExistingFurnaceorAirHandler, Horizontal Installation

Models: WPDV160XS WPDH160XS WGDV160UH WGDH160UH

1 16
Download 16 pages 13.24 Kb
Page 6
Image 6
InstallDehumidifier—ExistingFurnaceorAirHandler

InstallDehumidifier—ExistingFurnaceorAirHandler

Electrical Shock HazardWARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

NOTE: When using the existing duct system, the dehumidifier fan and the existing system fan must be interlocked by using the low voltage interlock method provided with the dehumidifier. See the wiring diagrams in the “Electrical Connections” section.

1.Disconnect power.

2.Place the dehumidifier in final location. See “Location Requirements.”

3.Attach ³⁄₄" PVC pipe to the condensate drain outlet. See “Location Requirements.”

4.Run the PVC pipe to an outdoor drain. Any horizontal run of drain pipe must have an anti-siphon vent for it to drain properly.

5.If needed, install a condensate pump kit (optional).

6.Using a 10" duct, attach the discharge air supply on the dehumidifier to the return air supply on the existing furnace or air handler.

NOTE: Install ductwork in accordance with NFPA 90B Standard for the Installation of Warm Air Heating and Air Conditioning Systems (latest edition) and any local codes.

7.Attach the return air supply on the dehumidifier to the return air supply on the existing furnace or air handler near the return air grille.

NOTE: Do not draw air directly from the kitchen, bathroom, laundry room or unconditioned isolated basement.

Disconnect power before servicing.WARNING

Excessive Weight Hazard

Use two or more people to move and install dehumidifier.

Failure to do so can result in back or other injury.

Horizontal Installation

AReplace all parts and panels before operating.Horizontal InstallationB

 

C

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

 

A. Return air from house

C. Dehumidifier

B. Existing return air duct

D. To existing furnace or air handler

6

Page 6
Image 6
Whirlpool WPDH160XS InstallDehumidifier-ExistingFurnaceorAirHandler, Horizontal Installation, Electrical Shock Hazard