Whirlpool WGDV160UH InstallationConfigurations, Vertical Installations Counterflow/Side Discharge

Models: WPDV160XS WPDH160XS WGDV160UH WGDH160UH

1 16
Download 16 pages 13.24 Kb
Page 4
Image 4
InstallationConfigurations

InstallationConfigurations

For ease in installation, it is best to make any necessary configuration changes before setting the dehumidifier in place. See “Installation Configuration Options” for the specific installation.

Vertical Installations

Counterflow/Side Discharge

The dehumidifier must be supported on the bottom only and set on a field-supplied supporting frame with a return air inlet opening. Securely attach the dehumidifier to the supporting frame.

Installation Configuration Options

A

B

 

C

A. Left discharge

B. Right discharge

C. Rear discharge

Horizontal Installations

Horizontal installations can be only right-hand air supply. The cabinet must be supported by the building structure to ensure cabinet integrity. Ensure that there is adequate room to remove the access panels if installing in the horizontal position. See Minimum Clearance Requirements in “Location Requirements.”

Installation Configuration Options

A

A. Left to right airflow

Suspended Cabinet Installation

NOTE: Ensure there is adequate room to remove the dehumidifier access panels. See Minimum Clearance Requirements chart in “Location Requirements.”

The suspending installation uses field-fabricated ³⁄₈"-16 all- thread rod passing through the top panel and connected to the dehumidifier base.

The ³⁄₈"-16 all-thread rod should be attached to the appropriate lengths of angle iron or equivalent structural steel which is attached to building structure capable of supporting the weight of the dehumidifier.

If the dehumidifier is not suspended by ³⁄₈"-16 all-thread rod, use the grommet plugs to cover the holes in the grommets.

Installation Configuration Options

A

B

C

A.³⁄₈"-16 all-thread rod

B.Grommet

C.Top panel

A

B

C

A.³⁄₈"-16 all-thread rod

B.³⁄₈" threaded hole

C.Dehumidifier base

4

Page 4
Image 4
Whirlpool WGDV160UH, WPDV160XS InstallationConfigurations, Vertical Installations Counterflow/Side Discharge, A B C