PERFORMANCE DATA SHEETS
Water Filtration System, models
Replacement Filter A (model WHAB-6009)
Replacement Filter B (model WHAB-6010)
Replacement Filter C (model WHAB-6011)
The system conforms to ANSI/NSF 42 and 53 for the specific performance claims as verified and substantiated by test data. The system has been tested according to ANSI/NSF 42 and 53 for reduction of substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in ANSI/NSF 42 and 53.
| DATA SHEET REDUCTION CLAIMS |
| |
ANSI/NSF STANDARD 42 |
| CARBON FILTER TESTED: Lead/Cyst | |
|
|
|
|
Substance | Influent challenge | Avg. | Reduction |
| concentration | % Rej. | requirement |
|
|
|
|
Chlorine, taste and odor | 2.0 mg/L ± 10% | 97.5 | 50% |
|
|
|
|
Particulate, Class I particles | At least 10,000 particles/ml | 97.0 | 85% |
0.5 mm to <1 mm
ANSI/NSF STANDARD 53 |
| CARBON FILTER TESTED: Lead/Cyst | |
Substance | Influent challenge | Avg. | Max. permissible product water |
| concentration mg/L | % Rej. | concentration mg/L |
Turbidity | 11 ± 1 NTU | 96.50 | 0.5 NTU |
Lead pH 6.5 | 0.15 ± 10% | 99.30 | 0.010 |
Lead pH 8.5 | 0.15 ± 10% | 99.30 | 0.010 |
VOC* | Refer to pages 17 and 18 for individual contaminant performance data. | ||
Mercury* | 0.006 ± 10% | 96.50 | 0.002 |
|
|
|
|
MTBE* | 0.015 ± 20% | 94.20 | 0.005 |
*VOC, MTBE and Mercury claims only apply when filter
Substance | Influent challenge | Avg. | Reduction |
| concentration | % Rej. | requirement |
Cysts | Min. 50,000/L | 99.99 | 99.95% |
Asbestos | 107 to 108 fibers/L: fibers | 99.00 | 99.00% |
| greater than 10 µm in length |
| |
NOTE: Certification for Cysts reduction includes Cryptosporidium and Giardia lamblia. | |||
OUTPUT PERFORMANCE | RATED AT CONTAMINANT REDUCTION TEST PARAMETERS |
SERVICE FLOW RATE AND CAPACITY
2.3Liters/minute (0.6 gallon/minute) Actual rate varies according to water pressure.
Capacity of 4542 Liters (1200 gallons)
NOTES:
Testing was performed under standard laboratory conditions. System performance may vary according to local water conditions.
Contaminants listed in this Data Sheet are not necessarily in your water. We recommend your water be tested to determine treatment requirements.
®NSF is a registered trademark of NSF International.