Whirlpool WHAB-6015 Performance Data Sheets, Water Filtration System, model WHAF-0435AC

Models: WHAF-0435AC WHAB-6012 WHAF-0335AB WHAB-6014 WHAB-6013 WHAB-6015

1 35
Download 35 pages 39.14 Kb
Page 17
Image 17
VOLATILE ORGANIC CHEMICALS/VOC's (continued)

PERFORMANCE DATA SHEETS

Water Filtration System, model WHAF-0435AC

Replacement Filter C (model WHAB-6011)

VOLATILE ORGANIC CHEMICALS/VOC's (continued)

CARBON FILTERS TESTED: 1m Extruded carbon, Lead/Cyst

Substance

Influent challenge

Max.permissible

Drinking water

 

concentration mg/L

product water

regulatory level1

 

 

concentration mg/L

(MCL/MAC) mg/L

1,1,2,2-tetrachloroethane

0.081

0.001

---

Tetrachloroethylene

0.081

0.001

0.005

Toluene

0.078

0.001

1.000

2,4,5-TP (silvex)

0.270

0.0016

0.050

Tribromoacetic acid

0.042

0.001

---

1,2,4-Trichlorobenzene

0.160

0.0005

0.070

1,1,1-Trichloroethane

0.084

0.0046

0.200

1,1,2-Trichloroethane

0.150

0.0005

0.005

Trichloroethelyne

0.180

0.001

0.005

Trihalomethanes (includes):

 

 

 

Chloroform (surrogate chemical)

0.300

0.015

0.080

Bromoform

0.300

0.015

0.080

Bromodichloromethane

0.300

0.015

0.080

Chlorodibromomethane

0.300

0.015

0.080

Xylenes (total)

0.070

0.001

10

Notes:

1.These harmonized values were agreed upon by representatives of USEPA and Health Canada for the purpose of evaluating products to the requirements of ANSI/NSF Standard 53.

2.Influent challenge levels are average influent concentrations determined in surrogate qualification testing.

3.Maximum permissible product water concentration was not observed but was set at the detection limit of the analysis.

4.Maximum permissible product water concentration is set at a value determined in surrogate qualification testing.

5.Maximum permissible product water level calculated at chloroform 95% breakthrough point as determined in surrogate qualification testing.

6.The surrogate test results for heptachlor epoxide demonstrated a 98% reduction. These data were used to calculate an upper occurrence concentration, which would produce a maximum product water level at the MCL.

For purchases made in Iowa:

This form must be signed and dated buy the buyer and seller prior to consummation of this sale. This form should be retained on file by the seller for a minimum of two years.

BUYER:

SELLER:

Name ________________________________________

Name __________________________________________________

Address _______________________________________

Address ________________________________________________

City ___________________________________________

City ____________________________________________________

State/Zip ______________________________________

State/Zip _______________________________________________

Signature/Date ________________________________

Signature/Date __________________________________

TESTED AND CERTIFIED TO ANSI/NSF® 42 & 53 FOR SPECIFIC CONTAMINANT CLAIMS AS VERIFIED AND SUBSTANTIATED BY TEST DATA

17

Page 17
Image 17