Troubleshooting
PROBLEM | CAUSE | CORRECTION |
|
|
|
Water has black or gray | (NEW SYSTEM) Start up procedure has | Run start up procedure (See Page 13) or |
color | not been completed | run consecutive Clean Rinse cycles (See |
|
| Page 15) until water color returns to nor- |
|
| mal. |
|
|
|
| (NOT A NEW SYSTEM) Normal abra- | Manually initiate a Clean Rinse cycle |
| sion of filtration media | (See Page 15). |
|
|
|
Low water pressure at | Sediment filter screen is clogged | Manually initiate a Clean Rinse cycle |
house faucets |
| (See Page 15). |
|
|
|
|
| Clean sediment filter screen (See Page |
|
| 20). If the filter screen is frequently plug- |
|
| ging, it may be necessary to adjust the |
|
| frequency of Clean Rinse cycles. |
|
|
|
| Filtration media is fouled | Manually initiate a Clean Rinse cycle |
|
| (See Page 15). |
|
|
|
|
| If the filtration media is frequently fouling, |
|
| it may be necessary to increase the fre- |
|
| quency of Clean Rinse cycles. |
|
|
|
Water has objectionable | System is in bypass | Move bypass valve(s) to normal operating |
taste and/or odor |
| |
|
|
|
| Filtration media is fouled | Manually initiate a Clean Rinse cycle |
|
| (See Page 15). |
|
|
|
|
| If the filtration media is frequently fouling, |
|
| it may be necessary to adjust the frequen- |
|
| cy of Clean Rinse cycles. |
|
|
|
No water flow to drain | System is in bypass | Move bypass valve(s) to normal operating |
during Clean Rinse cycle |
| |
|
|
|
| Drain flow control is plugged | Clean drain flow control (See Page 19). |
|
|
|
| Drain hose is plugged or kinked | Straighten drain hose. |
|
|
|
| Transformer is unplugged from wall | Check for loss of power and correct. |
| electrical outlet (display will be blank) |
|
|
|
|
Clean Rinse cycle does | If display reads “VAC”, then Clean | Press and release the CLEAN button until |
not run automatically | Rinse function has been disabled | display no longer reads “VAC”. |
|
|
|
| If display is blank, transformer may be | Check for loss of power. |
| unplugged from wall electrical outlet |
|
|
|
|
Clean Rinse cycle does | If time display is flashing, then a long | Reset the clock to the correct time of day |
not run at the pro- | power loss caused the clock to lose its | (See Page 14). |
grammed time of day | time setting |
|
Valve motor stalled or | Motor is defective or inner valve defect | Replace rotor/seal kit (instructions includ- |
clicking | is causing high torque on the motor | ed with kit). |
|
| Replace motor and switch (See parts list |
|
| at end of this manual). |
|
|
|
18