Troubleshooting
CLEANING THE SEDIMENT FILTER SCREEN
This procedure is not required if the Central Water Filtration System is operating normally. It should be performed only if a problem with low water pressure at household faucets is encountered, as detailed in the troubleshooting table on page 18.
1.Press and hold the CLEAN button for a few sec- onds, until “RECHARGE NOW” begins to flash in the display.
2.When water begins to flow from the valve drain hose, place the bypass valve(s) in bypass position (See Figure 11 on Page 12).
IMPORTANT: Be sure to do Steps 1 and 2, as instruct- ed, to relieve water pressure in the tank.
3. | Unplug the transformer from the wall electrical out- |
| let. |
4. | Remove the cover and hang it from the post on |
| front of rim (See Figure 9 on Page 10). |
5. | Pull the two clips at the inlet and outlet fittings. |
| Slide the adaptors, or bypass valve, from the |
| Central Water Filtration System valve. |
6. | Remove the clamp retainers (2) and clamp sections |
| (2) that hold the valve to the tank (See Figure 25). |
| Lift upward to remove the valve. |
7. | Remove the small |
8. | Remove the screen from the top distributor. Rinse |
| off the screen. |
9. | Use water to flush the tank top opening. Then, |
| replace the top distributor and |
| located |
FIG. 24
REMOVING VALVE ASSEMBLY
| Clips (2) |
Valve | Bypass |
Clamp | Valve |
Sections (2) |
|
Retainers (2)
FIG. 25
REASSEMBLING FILTER SCREEN
10. | Install the valve assembly and retaining clamps. |
| Double check to be sure clamps and retainers are |
| securely fastened in place. |
11. Referring to the installation instructions, reconnect | |
| the Central Water Filtration System to the plumb- |
| ing. Be sure the plumbing is held firmly in place in |
| the valve inlet and outlet. |
12. | Return the plumbing bypass valve(s) to normal |
| operating position |
13. | Plug the transformer back into the wall electrical |
| outlet. The Central Water Filtration System will |
| complete the Clean Rinse cycle initiated in Step 1, |
| and will automatically return to normal operation. |
Filter Screen
Top
Distributor
Small
Large
Rim |
Tank |
Stand pipe |
FIG. 26
20