Whirlpool WHELJ1 Cleaning The Sediment Filter Screen, Removing Valve Assembly, Troubleshooting

Models: WHELJ1

1 27
Download 27 pages 18.31 Kb
Page 20
Image 20
CLEANING THE SEDIMENT FILTER SCREEN

Troubleshooting

CLEANING THE SEDIMENT FILTER SCREEN

This procedure is not required if the Central Water Filtration System is operating normally. It should be performed only if a problem with low water pressure at household faucets is encountered, as detailed in the troubleshooting table on page 18.

1.Press and hold the CLEAN button for a few sec- onds, until “RECHARGE NOW” begins to flash in the display.

2.When water begins to flow from the valve drain hose, place the bypass valve(s) in bypass position (See Figure 11 on Page 12).

IMPORTANT: Be sure to do Steps 1 and 2, as instruct- ed, to relieve water pressure in the tank.

3.

Unplug the transformer from the wall electrical out-

 

let.

4.

Remove the cover and hang it from the post on

 

front of rim (See Figure 9 on Page 10).

5.

Pull the two clips at the inlet and outlet fittings.

 

Slide the adaptors, or bypass valve, from the

 

Central Water Filtration System valve.

6.

Remove the clamp retainers (2) and clamp sections

 

(2) that hold the valve to the tank (See Figure 25).

 

Lift upward to remove the valve.

7.

Remove the small o-ring (See Figure 26).

8.

Remove the screen from the top distributor. Rinse

 

off the screen.

9.

Use water to flush the tank top opening. Then,

 

replace the top distributor and o-ring. Be sure to

 

located o-ring seal correctly (See Figure 26).

FIG. 24

REMOVING VALVE ASSEMBLY

 

Clips (2)

Valve

Bypass

Clamp

Valve

Sections (2)

 

Retainers (2)

FIG. 25

REASSEMBLING FILTER SCREEN

10.

Install the valve assembly and retaining clamps.

 

Double check to be sure clamps and retainers are

 

securely fastened in place.

11. Referring to the installation instructions, reconnect

 

the Central Water Filtration System to the plumb-

 

ing. Be sure the plumbing is held firmly in place in

 

the valve inlet and outlet.

12.

Return the plumbing bypass valve(s) to normal

 

operating position (non-bypass).

13.

Plug the transformer back into the wall electrical

 

outlet. The Central Water Filtration System will

 

complete the Clean Rinse cycle initiated in Step 1,

 

and will automatically return to normal operation.

Filter Screen

Top

Distributor

Small O-ring

Large O-ring

Rim

Tank

Stand pipe

FIG. 26

20

Page 20
Image 20
Whirlpool WHELJ1 Cleaning The Sediment Filter Screen, Removing Valve Assembly, Reassembling Filter Screen, Troubleshooting