WhisperKool 081310, GSM-01 owner manual Liquid Measuring Thermometer, To use the thermostat

Models: 081310 GSM-01

1 34
Download 34 pages 8.66 Kb
Page 13
Image 13
LIQUID MEASURING THERMOMETER

LIQUID MEASURING THERMOMETER

Most WhisperKOOL systems come equipped with a liquid temperature measuring thermometer probe . This self calibrating probe contains a sensor chip, which actually communicates back and forth to the thermostat. This results in a consistent liquid temperature as air temperature fluctuates

Measuring liquid temperature has a couple unique advantages:

1.The temperature of the wine can be more precisely controlled, ensuring a more consistent overall temperature.

2.The system will switch on/off less often, extending cooling system life.

To use the thermostat:

1.Fill an empty wine bottle 3/4 full with room temperature tap water

2.Press bottle probe securely into bottle

3. Place the bottle with probe into a level rack space. Avoid pull- ing too much on the probe cord, it may become disconnected resulting in non-operation of the unit.

Remember: The WhisperKOOL System maintains cellar environ- ment based on the liquid temperature. It is ideal to place the probed bottle lower in the racking so that it is not near cold supply air.

Note: When performing a ducted or remote installation, it is cru- cial to not forget about routing the bottle probe into the cellar. The system must have the sensing bottle in the cellar to maintain the cellar environment.