Energy | 1. | The ER feature can be used to save energy and aids in extending the life of the system. |
Reduc- | 2. | The ER button is located at the top L/H side of the control. The ER feature is activated by |
tion | pressing the ER button one time, and the ER logo will appear on the digital display. | |
(ER) | 3. | The purpose of the ER feature is to reduce energy cost, by shifting the Set Point up by 4 de- |
| grees, which will allow the cooling system to run for shorter periods of time, resulting in a reduc- | |
| tion in energy cost. | |
| 4. | The ER feature allows for Energy Savings at any time - During periods of high ambient tem- |
| peratures, vacations or business travel. | |
| 5. | To deactivate the ER feature, press the ER button one time, and the ER logo will turn off. |
| 6. | The ER feature can be conveniently adjusted to the customer’s specific needs, by accessing |
| the “Customer Preference Select Mode” (CPSM). See Customer Preference Select Mode Instruc- | |
| tions. | |
| Note: This feature is not available on the Remote Key Pad application. | |
Set | 1. | Press the “Set” button once and it will display the Set Point. After approximately 5 seconds, |
Button | the display will return to normal operation and display the Bottle Probe temperature. | |
| 2. | Press and hold the “Set” button for |
| bol starts blinking. Next press the “UP or Down” arrows to change the Set Point. Next press the | |
| “Set” button once and the Set Point numbers and the °F on the display will blink to confirm the | |
| new Set Point setting. | |
| 3. | Press and hold the “Set” button during the display of the Hi/Low “Temperature Data History” |
| (hold button unit “rst” blinks on display), and it will erase the past recorded data file and start | |
| recording, from the current time and temperature. | |
| 4. | Press the “Set” and the “Down Arrow” buttons simultaneously, for |
| cess the “Customer Preference Selection Mode” (CPSM). The CPSM allows the customer to “Fine | |
| Tune” the Control Operating System to their applicable choice. | |
CPSM | Press the “Set” and the “Down Arrow” buttons simultaneously, for | |
Mode | cess the “Customer Preference Selection Mode” (CPSM). The CPSM allows the customer to “Fine | |
| Tune” the Control Operating System to their applicable choice. | |
| The following CPSM options are available for adjustment: |
Fon – Humidity Management Enhancement: This parameter is normally set at 5, which should provide adequate relative humidity for the cellar.
•An increase in this parameter will increase the Humidity Enhancement (%RH), and a decrease in the parameter will decrease Humidity Enhancement (%RH).
•Adjustments should be made in increments of 5, with a maximum of 15, and a minimum of 0.
•After any adjustment to Humidity Enhancement, you should wait a minimum of three days before making any additional adjustments. This will allow the cellar sufficient time to accli- mate to the new setting.
Fof - Humidity Management Enhancement: This parameter is normally set at 1. This parameter should not be adjusted, as it simply provides an OFF cycle time for the fan, during the compres- sor OFF cycle. However, the parameter is located within the CPSM as a convenience to the cus- tomer, should it need to be adjusted.
Page 14 |