TROUBLESHOOTING
Display Alarm Codes
Message | Cause | Outputs |
|
|
|
“P1” | Room probe failure | Compressor output acc. to par. “Con” and “COF” |
|
|
|
“P2” | Evaporator probe failure | Defrost end is timed |
|
|
|
“HA” | Max bottle probe temp alarm | Outputs unchanged |
|
|
|
“LA” | Min bottle probe temp alarm | Outputs unchanged |
|
|
|
“EA” | External alarm | Outputs unchanged |
|
|
|
Fault
Cause
Solution
Water leaking from unit
|
| 1. Condensate drain | Clear out drain |
|
| clogged |
|
|
|
|
|
|
| 2. Evaporator coil | Clean the coil and / or fan wheel |
|
| frozen |
|
|
|
|
|
|
| 3. Drain line improperly | Call a CERTIFIED HVAC service technician. |
|
| installed |
|
|
|
|
|
| Wine cellar temperature above thermostat set point | ||
|
|
|
|
|
| 1. Large quantity of warm | Allow time for wine to cool |
|
| wine placed in cellar |
|
|
|
|
|
|
| 2. Wine Cellar Door left | Close Door. Allow time for wine to cool. |
|
| open for long period. |
|
|
|
|
|
|
| 3. No power to either | Is the thermostat display illuminated? |
|
| evaporator or condensing | If not, check power supply switch, if equipped. Ensure it is in the |
|
| unit | ON position. |
|
|
| If on, check to see in the breaker is tripped. |
|
|
| If tripped, reset and check display. |
|
|
| Check breaker to condensing unit. If tripped, check to see if com- |
|
|
| pressor is hot – too hot to touch. If so, allow to cool for one (1) |
|
|
| hour before resetting breaker. |
|
|
| After cooling, reset breaker and note whether it remains set or |
|
|
| trips off. If it trips, call a CERTIFIED HVAC service technician for |
|
|
| repair. |
|
|
|
|
Page 17