TROUBLESHOOTING

TROUBLESHOOTING

Display Alarm Codes

Message

Cause

Outputs

 

 

 

“P1”

Room probe failure

Compressor output acc. to par. “Con” and “COF”

 

 

 

“P2”

Evaporator probe failure

Defrost end is timed

 

 

 

“HA”

Max bottle probe temp alarm

Outputs unchanged

 

 

 

“LA”

Min bottle probe temp alarm

Outputs unchanged

 

 

 

“EA”

External alarm

Outputs unchanged

 

 

 

Fault

Cause

Solution

Water leaking from unit

 

 

1. Condensate drain

Clear out drain

 

 

clogged

 

 

 

 

 

 

 

2. Evaporator coil

Clean the coil and / or fan wheel

 

 

frozen

 

 

 

 

 

 

 

3. Drain line improperly

Call a CERTIFIED HVAC service technician.

 

 

installed

 

 

 

 

 

 

Wine cellar temperature above thermostat set point

 

 

 

 

 

 

1. Large quantity of warm

Allow time for wine to cool

 

 

wine placed in cellar

 

 

 

 

 

 

 

2. Wine Cellar Door left

Close Door. Allow time for wine to cool.

 

 

open for long period.

 

 

 

 

 

 

 

3. No power to either

Is the thermostat display illuminated?

 

 

evaporator or condensing

If not, check power supply switch, if equipped. Ensure it is in the

 

 

unit

ON position.

 

 

 

If on, check to see in the breaker is tripped.

 

 

 

If tripped, reset and check display.

 

 

 

Check breaker to condensing unit. If tripped, check to see if com-

 

 

 

pressor is hot – too hot to touch. If so, allow to cool for one (1)

 

 

 

hour before resetting breaker.

 

 

 

After cooling, reset breaker and note whether it remains set or

 

 

 

trips off. If it trips, call a CERTIFIED HVAC service technician for

 

 

 

repair.

 

 

 

 