The air coming out of | ∙ The filters are dirty or | ∙ Clean the air filters. | |
the unit is not very | obstructed. |
| |
cold, or the airflow | ∙ The air intake or exhaust is | ∙ Make sure there is at least 20" of clearance from | |
volume is weak | obstructed. | the air intake. Make the length of the exhaust hose | |
|
| is as short as possible. | |
| ∙ The unit is set in DRY or | ∙ Set the unit to the cooling mode. | |
| FAN mode. |
| |
| ∙ The unit is set to low fan | ∙ Set the unit to a higher fan speed. | |
| speed. |
| |
|
|
| |
The unit has worked for | ∙ Windows or doors are open. | ∙ Close all windows and doors. | |
|
| ||
a long time, but the | ∙ There are too many people | ∙ You may need additional cooling or another air | |
room is not cold | |||
in the room. | conditioner. | ||
enough | |||
|
| ||
| ∙ There is direct sunshine into | ∙ Close curtains or blinds and try to minimize the | |
| the room. | amount of direct sunlight into the room. | |
| ∙ The room is a kitchen or | ∙ You may need additional cooling or another air | |
| with many | conditioner. | |
| appliances |
| |
| ∙ There is a server in the | ∙ You may need additional cooling or another air | |
| room. | conditioner. | |
| ∙ The room is too large. | ∙ You may need additional cooling or another air | |
|
| conditioner. | |
The unit is very noisy | ∙ The unit is not level. | ∙ Make sure the unit is on hard, level and stable | |
| surface. | ||
|
| ||
| ∙ The surface underneath the | ∙ Move the unit to a location with a level and hard | |
| unit is uneven. | floor. | |
| ∙ Low power voltage. | ∙ Make sure the wall outlet and support the required | |
|
| power consumption of the air conditioner and do | |
|
| not use an extension cord. | |
The unit leaks water | ∙ The unit is tilted or not | ∙ Make use the unit is leveled. | |
leveled |
| ||
|
| ||
| ∙ The water tank is full. | ∙ Drain water from the drain plug at the back of the | |
|
| air conditioner. | |
The unit needs to be | ∙ The humidity in the area | ∙ Remove the intake hose if the outside humidity is | |
may very high | high or it is raining | ||
drained too often | |||
|
| ||
| ∙ Possible loose connection | ∙ Contact Whynter Service Department | |
Fan speed cannot be | ∙ Fan speed differences are | ∙ The fan speed difference is not very noticeable | |
not very noticeable | when the compressor is on. Try setting the unit to | ||
changed | |||
| Fan only mode, you should be able to hear the | ||
|
| ||
|
| difference between high and low fan speed | |
|
| settings. |