Manual Liquid Dispensing Mode

This feature sets up the SD2 unit to dispense coffee only as long as the user holds down the selected PUSH button.

As soon as the user stops pressing the button, coffee stops flowing into the cup. Setting the unit for Manual Liquid Dispense will turn off the Portion Control Dispense Mode.

Enter

Program Mode

Select Manual Liquid Dispense

Enter Program Mode – press and hold STOP/WASH for about ten [10] seconds until all lights on the control panel are blinking.

Set Manual Dispense – While you are in the programming mode, press and hold the PUSH button. Hot liquid will start to flow.

Continue to hold down the PUSH button until liquid stops flowing, then release the button.

Stop & Exit

At this time, you have selected the Manual Liquid Dispensing Mode and have exited out of the programming mode.

Confirm/Reset Temperature

These features allow you to check the heating tank temperature or change the temperature if desired. The temperature in the tank is programmable from 170°F, in 2 degree increments up to 204°F .

 

 

 

 

Temperature Settings

To Confirm Temperature. Press and hold STOP/WASH button for approximately 2-3 seconds. When the READY light

 

Number of

 

starts blinking. Lift off from STOP/WASH button. Each blink equals 2ºF, starting with 170ºF, to a maximum of 204ºF.

 

Blinks

Temperature

 

 

 

 

1

170ºF

To Change Tank Temperature

 

2

172ºF

 

3

174ºF

 

 

 

 

4

176ºF

Enter

 

Enter Temperature Program Mode. Press and hold STOP/WASH button. READY light will

5

178ºF

Temp. Program

start “quick flashing”.

 

6

180ºF

 

7

182ºF

 

 

 

 

 

 

 

8

184ºF

 

 

 

9

186ºF

 

 

 

 

 

 

 

 

To Change Temperature. Continue holding STOP/WASH button. Each quick flash equals

 

10

188ºF

Change

11

190ºF

Tank Temp.

2ºF. Release STOP/WASH when desired temperature is reached.

 

 

 

 

12

192ºF

 

 

 

 

13

194ºF

 

 

 

 

 

 

 

14

196ºF

 

 

 

 

15

198ºF

 

 

 

 

 

 

 

16

200ºF

Set & Exit

To Set and Exit, press either of the PUSH buttons.

 

17

202ºF

18

204ºF

 

 

 

 

 

 

 

 

 

LOW TEMPERATURE LOCKOUT (DELTA): This mode will give you a choice of two minimum operating temperatures. Delta one allows you to operate the unit at a temperature as low as 195º F. Delta two will allow you to dispense at a temperature as low as 185º F. Delta three does not limit the minimum operating temperature. The Cafe system comes from the factory with a Delta three setting. To make adjustments enter Program Mode:

1.Press and hold Stop/Wash button, until all lights on the control panel are blinking, about 10 seconds. Release button.

2.While in the Program Mode, press and hold Stop/Wash button the READY light will begin blinking, continue to hold the Stop/Wash button. The READY light will stop blinking. Continue holding Stop/Wash button until the READY light comes back on in a longer, 3 second glow.

3.Now release the Stop/Wash button The READY light will now blink a pattern of flashes indicating current delta setting.

DELTA ONE (one long glow, followed by one blink) allows you to run the coffee dispense at five degree below maximum. DELTA TWO (one long and two blinks) allows you to run the coffee dispense at 15 degrees below maximum.

DELTA THREE (one long and three blinks) allows you to operate the unit at any temperature.

4. To change the setting, press and hold the Stop/Wash button for about three seconds until you receive a short flash. Release the button and you will

add one blink to the delta pattern or continue holding to add two blinks.