WindChaser Products PACR12 Troubleshooting Guide, Problem, Probable Causes, Solutions

Models: PACR12

1 16
Download 16 pages 3.51 Kb
Page 13
Image 13
TROUBLESHOOTING GUIDE

TROUBLESHOOTING GUIDE

When the air conditioner does not work, it is sometimes a minor problem which the user can handle. Before calling customer service, please check the following points to see if they solve your problem. Additional troubleshooting tips may be found on our website at: www.windchaserproducts.com.

Problem

Probable Causes

 

Solutions

 

 

 

 

The air conditioner/dehumidifier

1) Plug not properly inserted into

1)

Plug the appliance in properly.

doesn’t work.

wall socket.

 

 

 

2) Insufficient amount of amperage

2)

Check circuit board for

 

to start unit.

 

15-20amp fuse availability.

 

3) Water tank is full / alarm light

3)

Check Drain (A) for obstruction

 

illuminated.

 

and/or empty Drain (B).

 

 

 

 

The air conditioner cuts off.

1) Exhaust hose too long, run

1)

Exhaust hose can only be

 

incorrectly or kinked.

 

extended using max. 5’ of 4”

 

 

 

PVC pipe for a total exhaust

 

 

 

length of 10’.

 

2) Unit too close to wall or object.

2)

Unit should be at least 1 ½’

 

 

 

away from walls and objects

 

3) Flap vent obstructs wall

3)

Use screen instead of Flap vent

 

exhaust.

 

for wall exhaust.

 

4) Ceiling or basement does not

4)

Unit will overheat if the exhaust

 

have ample ventilation.

 

cannot fully vent.

 

5) The “timer off” function has been

5)

Push the power button to turn unit

 

activated.

 

on.

 

 

 

 

The air conditioner/

1) In the A/C function, the ambient

1)

This is normal. Set the

dehumidifier LED indicator

temperature has reached the set

 

temperature lower to turn the

light blinks.

temperature and therefore the

 

compressor back on.

 

compressor has shut off.

 

 

 

2) In the dehumidifier function, the

2)

This is normal.

 

humidity in the room is 50% or

 

 

 

lower and therefore the

 

 

 

compressor is not running.

 

 

The LED display shows the

The unit’s “timer on” feature is

1)

This is normal.

unit is set, but the unit is not

activated.

 

 

running.

 

2) Push the Power button to turn the

 

 

 

unit on and deactivate the “timer

 

 

 

on” feature.

 

 

 

The Alarm Indicator Light is

The condensate tank is full and

If you are using Drain (A), make

Illuminated

the unit cannot drain. This safety

sure that the drain hose is no more

 

feature turns off the unit to protect

than 5.9 feet above the ground. If

 

the unit and prevent the

Drain (A) still does not work, the

 

condensate tank from overflowing.

condensate must be drained

 

 

through Drain (B). After draining

 

 

the tank, you should be able to

 

 

restart and use the unit.

 

 

 

11

 

 

 

Page 13
Image 13
WindChaser Products PACR12 instruction manual Troubleshooting Guide, Problem, Probable Causes, Solutions