TROUBLESHOOTING CONT.
Solution hose | Corrosion on fittings | Clean with steel wool. |
|
fitting hard to |
| Soak in acetic acid (white vinegar). | |
connect |
| Lubricate lightly with silicone base | |
|
| lubricant. |
|
Carpet not | Severe soil conditions | Make several passes at right angles to | |
getting clean. |
| other. Use a prespray. |
|
Carpet too wet | Over saturation | Adjust solution pressure to lower setting. | |
|
| Make several passes without spray. | |
Carpet browning | Leaving carpet too wet | Check for loss of vac pressure. | |
| Too much chemical in | Check label for correct solution | |
|
| concentration. | . |
Solution not | Solution hose connection | Check for positive connection | |
flowing properly | Faulty pump | Repair or replace. |
|
|
| ||
| Faulty floor tool valve | Repair or replace. |
|
| Faulty pump switch | Repair. |
|
TECHNICAL SPECIFICATIONS
POWER TYPE
ELECTRICAL: 115 V, 60 Hz, 15 Amps per power cable ((D250) 230 V, 50 Hz, 15 Amps (D250IE)
ELECTRIC VACUUM MOTOR: (1)
SOLUTION PUMP: 250 psi, adj.
SOLUTION CAPACITY: 17 gallons (64.3ltr)
RECOVERY CAPACITY: 15 gallons (56.75ltr)
GENERAL DIMENSIONS/WEIGHT
WEIGHT: 97 lbs. ( 44 kg)
LENGTH: 20” (50.80 cm)
HEIGHT: 36” (91.44 cm)
WIDTH: 16” (40.64 cm)
POWER CABLE:
10 | |
|