DAILY MAINTENANCE:

(At the end of each working day) :

1.) Flush the entire system, including floor tool, hand tool, etc., with 1 to 3 gallons of clean, hot water.

2.) Vacuum out the solution tank .

3.) Rinse tank with fresh water. Periodically inspect the recovery tank and decontaminate if necessary, using a Hospital Grade Virucide or a 1-10 bleach to water solution. Waste water should be disposed of properly.

4.) Remove lint build-up from the float shut-off screen in the recovery tank . (Occasionally check filter screen at the bottom of the solution tank and rinse clean with hot water if necessary).

5.) Inspect hoses for wear. Frayed or cracked hoses should be replaced to avoid vacuum or solution pressure loss.

6.) Inspect power cord for wear or damage. This cable will lay on wet carpet. To prevent electrical shock replace cords that are frayed or have cracked insulation immediately.

7.) Ensure automatic shut-off ball is working properly.

8.) Clean all dirt and obstructions from drain valve and gaskets to prevent possible leakage and premature wear.

9.) Run clean water through solution pump when work is complete.

10.) Empty both tanks and rinse, run vacuum (s) for at least one minute to dry motor(s).

11.) Store with access covers removed to allow tanks to dry.

PERIODIC MAINTENANCE

1.) Twice a month, flush a white vinegar solution (One quart vinegar to two gallons of water) or anti-browning solution (mixed as directed) through the extractor, turning pump switch on/off several times, flush with clean water. This will prevent build-up of alkaline residue in the system.

2.) Check hoses for wear, blockages, or damage. Frayed or cracked hoses should be repaired or replaced to eliminate vacuum or solution pressure loss.

MAINTENANCE

3.) Check all handles, switches, knobs, electrical cables and connections on your machine for damage. If the cable insulation is broken or frayed, repair or replace it immediately. Don’t take chances with electrical fire or shock.

4.) Clean out solution tank and remove and clean solution screen.

5.) Clean outside of all tanks and check for damage.

MONTHLY MAINTENANCE

1.) Check all bearings for noise and wear.

2.) Check all gaskets for wear and leakage.

3.) Check pump pressure; observe spray pattern and check with gauge if necessary.

4.) Check overall performance of machine.

5.) Grease piston inside pressure regulator.

SEMI-ANNUALLY

1.) Check vacuum motor brushes.

LUBRICATION

For hose fitting lubrication, use a light silicone lubricant which will not damage o-rings.

STORAGE

Thoroughly clean machine if it is to be stored. Protect this machine from freezing while in storage.

HEATER MODEL STORAGE

Be sure to thoroughly drain water out of heater lines prior to storage in colder climates. This heater will freeze and possibly crack, voiding your warranty.

D-250 98828 04/08/03

6

Page 7
Image 7
Windsor D250 (115V) manual Maintenance

D250 (115V) specifications

The Windsor D250 (115V) is a powerful and versatile floor scrubber designed to meet the cleaning needs of various commercial environments. Known for its durability and efficiency, the D250 is an excellent choice for facilities management in schools, warehouses, retail spaces, and healthcare settings.

One of the standout features of the Windsor D250 is its compact design. This makes it easy to maneuver in tight spaces and provides superior cleaning capabilities even in hard-to-reach areas. The unit is built with a high-performance motor that delivers consistent power, ensuring it can tackle heavy-duty cleaning tasks without compromising performance.

Equipped with a dual scrub deck, the D250 utilizes two counter-rotating brushes that improve dirt and stain removal. This technology allows for effective scrubbing without the hassle of frequent brush changes or complicated maintenance. The scrub deck can be easily adjusted depending on the surface type, allowing for versatility in cleaning applications from smooth floors to textured surfaces.

The D250 features a user-friendly control panel that simplifies operation. With intuitive controls, even staff with minimal training can quickly become proficient in using the machine. Additionally, the adjustable handle provides ergonomic benefits, reducing operator fatigue during prolonged use.

In terms of water management, the Windsor D250 incorporates an efficient solution distribution system. This ensures optimal water usage, minimizing waste while maximizing cleaning efficiency. The recovery tank design is also noteworthy; it features an easy-to-empty design that facilitates the swift removal of dirty water, accelerating the cleaning process.

The D250 is designed for durability with high-quality materials that enhance its lifespan. Furthermore, its low noise operation makes it suitable for use in noise-sensitive areas, allowing cleaning to take place without disrupting regular activities.

For maintenance, the Windsor D250 requires minimal intervention. With access to components such as brushes and filters easily available, routine maintenance becomes a straightforward task. This aspect of design not only saves time but also reduces operational costs.

Overall, the Windsor D250 (115V) is a commendable floor scrubber that combines innovative technology with user-friendly features. Its robust construction, effective cleaning capacity, and ease of use make it a reliable choice for any commercial cleaning environment. Whether for heavy-duty applications or routine maintenance, the D250 is engineered to get the job done efficiently while ensuring the highest standards of cleanliness.