Gas Supply Requirements

GAS MANIFOLD PRESSURE

Natural Gas: Standard orifices are set for 5" (12.5 mb) WC. A natural gas pressure regulator is installed.

LP Gas: Standard orifices are set for 10" (25 mb) WC. An LP gas pressure regulator is installed.

Gas Supply Pressure: The maximum gas supply pressure to the regulator should never exceed 14"

(34.9 mb) WC; .5 psi (3.5 kPa) for natural and LP gas. The minimum line pressure is 7" (17.5 mb) WC for natural gas and 11" (27.4 mb) WC for LP gas.

Gas Pressure Regulator: To control and maintain a uniform gas pressure in the gas manifold, the unit must be used with a gas pressure regulator. The burner orifices, etc. are sized for the gas pressure delivered by the supplied regulator. Do not remove the regulator.

The maximum gas supply pressure to the regulator should never exceed 14" (34.9 mb) WC; .5 psi (3.5 kPa).

Electrical Requirements

ELECTRICAL SHOCK HAZARD: Plug into a grounded 3-prong outlet. Do not remove ground prong. Do not use an adapter. Failure to follow these instructions can result in electric shock, fire or death.

The Wolf gas cooktop requires a 120 V AC, 60 Hz electri- cal supply to operate the electronic ignition system. The service should have its own 15 amp circuit breaker. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.

The cooktop is equipped with a power cord with a 3-prong grounding plug. To minimize shock hazard, the power cord must be plugged into a mating 3-prong grounded outlet, grounded to conform with the National Electrical Code, ANSI/NFPA 70 latest edition, or Canadian Electrical Code (CSA) and all local codes and ordinances. Refer to the illustration below.

IMPORTANT NOTE: Do not ground to a gas pipe.

WIRING DIAGRAM

A wiring diagram covering the control circuit for each gas cooktop model can be found on the following page.

GROUNDING

PLUG

GROUNDED

ELECTRICAL OUTLET

Electrical ground.