Wolf 814990 Verify Cooktop Operation, GAS Supply Connection, GAS Leak Testing, Surface Burners

Models: 814990

1 16
Download 16 pages 40.07 Kb
Page 14
Image 14

Gas Cooktop Installation

14

 

 

Install the Cooktop

GAS SUPPLY CONNECTION

Assemble the flexible metal connector from the gas supply pipe to the gas pressure regulator. You will need to deter- mine the fittings required, depending on the size of your gas supply line, flexible metal connector and shut-off valve. Refer to the illustration below.

Use a pipe joint compound made for use with natural and LP gas. If a flexible metal connector is used, be sure the tubing is not kinked.

Open the shut-off valve in the gas supply line. Wait a few minutes for the gas to move through the line. Refer to the illustration on page 10.

GAS LEAK TESTING

Use a brush and liquid detergent to test all gas connec- tions for leaks. Bubbles around connections will indicate a leak. If a leak appears, shut off the gas supply and adjust connections. Then check connections again. Clean the detergent solution from the cooktop.

Never test for a gas leak with a match or other flame.

Verify Cooktop Operation

SURFACE BURNERS

The surface burners use electronic igniters in place of standing pilots. When the cooktop control knob is pushed in and turned to the HIGH position, the system creates a spark to light the burner. This sparking continues until the electronic ignition senses a flame.

Before lighting, place the burner head and cap on each burner base and position the burner grates.

To check operation of the surface burners, push in and turn each control knob to the HIGH position. The flame should light within four seconds.

If the burners do not light properly, turn each control knob to the OFF position. Check that burner heads and caps are in the proper position. Check that the power cord is plugged in and that the circuit breaker or house fuse has not blown. Check that the gas shut-off valve is in the open position. Check operation again, waiting at least five minutes; if the burners do not light properly, contact a Wolf authorized service center.

IMPORTANT NOTE: Initial lighting of the surface burners may take slightly longer, as air in the system must be purged before gas can be supplied to the burner.

SHUT-OFF

 

GAS PRESSURE

VALVE

 

REGULATOR

ADAPTER

 

ADAPTER

NIPPLE

FLEXIBLE

NIPPLE

METAL CONNECTOR

Gas supply connection.

Page 14
Image 14
Wolf 814990 manual Verify Cooktop Operation, GAS Supply Connection, GAS Leak Testing, Surface Burners