Wolf MWD30-2U/S, MWD30-2F/S manual Clea NI NG and C are, Do not use abrasive or harsh cleaners or

Models: MWD30-2F/S MWD30-2U/S

1 32
Download 32 pages 54.21 Kb
Page 28
Image 28

WO LF D RAWER MIC ROWAVE CARE

CLEA NI NG AND C ARE

S TAIN LES S STEE L S U RFA CE

The exterior should be wiped often with a soft damp cloth and polished with a soft dry cloth to maintain its beauty. There are also a variety of products designed especially for cleaning and shining the stainless exterior of the oven. We recommend that the cleaner be applied to a soft cloth and then carefully used on the stainless exterior rather than sprayed directly on to it. Follow package directions carefully.

FR ON T S ID E OF THE D RA WER

Wipe the window on both sides with a soft damp cloth to remove any spills or spatters. Metal parts will be easier to maintain if wiped frequently with a soft damp cloth. Avoid the use of spray and other harsh cleaners as they may stain, streak or dull the door surface.

TO UC H CO N TR OL PANEL

If desired, the touch pads may be deactivated before cleaning. See the CONTROL LOCK infor- mation on page 25 of this manual. Wipe the panel with a cloth dampened slightly with water only. Dry with a soft cloth. Do not scrub or use any sort of chemical cleaners. Close door and follow directions on page 25 for turning CONTROL LOCK off. Touch

STOP/CLEAR.

I N TE R I O R

Cleaning is easy because no heat is generated to the interior surfaces; therefore, there is no baking and setting of spills or spattering. To clean the interior surfaces, including drawer sealing surfaces, wipe with a soft damp cloth.

Do not use abrasive or harsh cleaners or

scouring pads. For heavier soil, use mild soap; wipe clean with a soft damp cloth. Do not use any chemical oven cleaners.

DR AW ER GU ID E S

Remove the food crumbs from the drawer guides. Wipe with a soft dry cloth in order to keep the drawer microwave opening and closing smoothly.

The waveguide cover, located on the inside top of the drawer microwave area, is made from mica, so it requires special care. Keep the waveguide cover clean to assure good microwave performance. Carefully wipe with a soft damp cloth any food spatters from the surface of the cover immediately after they occur. Built-up splashes may overheat and cause smoke or possibly catch fire. Do not remove the waveguide cover.

OD O R RE MO VA L

Occasionally, a cooking odor may remain in the drawer microwave. To remove, combine

1 cup (250 ml) water, grated peel and juice of one lemon and several whole cloves in a 2-cup (500 ml) glass measuring cup. Boil for several minutes using 100% power. Allow to set in the drawer microwave until cool. Wipe interior with a soft cloth.

28

Page 28
Image 28
Wolf MWD30-2U/S, MWD30-2F/S manual Clea NI NG and C are, Do not use abrasive or harsh cleaners or

MWD30-2F/S, MWD30-2U/S specifications

The Wolf MWD30-2U/S and MWD30-2F/S models are innovative heating solutions designed to cater to various domestic and commercial heating needs. These wall-mounted gas condensing boilers embody cutting-edge technology, ensuring efficiency, reliability, and high-performance heating.

One of the standout features of the MWD30-2U/S and MWD30-2F/S models is their impressive energy efficiency rating. By utilizing advanced condensing technology, these boilers maximize heat extraction from the fuel, significantly reducing energy consumption and associated costs. They boast an efficiency level of over 90%, making them environmentally friendly and cost-effective heating solutions.

Both models are equipped with a robust heat exchanger, which plays a crucial role in enhancing the heat transfer process. The stainless steel construction of the heat exchanger ensures durability and longevity, enabling the units to perform optimally over extended periods. This construction also aids in minimizing the risk of corrosion, ensuring consistent heat output.

The Wolf MWD30-2U/S and MWD30-2F/S models come with a user-friendly interface, allowing for easy operation and monitoring. The digital display provides real-time information on the boiler's performance, including temperature settings and operational status. This feature empowers users to make informed adjustments and maintain comfort levels efficiently.

In terms of installation flexibility, these boilers are designed for various configurations, making them suitable for different spaces and layouts. Their compact size allows for easy fitting in limited spaces, such as utility rooms or basements. Furthermore, with a range of flue options available, these models can be adapted to meet the specific requirements of any installation site.

Another vital characteristic is the exceptional safety features incorporated into the MWD30-2U/S and MWD30-2F/S units. These models have built-in safety mechanisms, including pressure monitoring and overheat protection, ensuring reliable operation while maintaining peace of mind for users.

In conclusion, the Wolf MWD30-2U/S and MWD30-2F/S models stand out in the modern heating market, combining advanced technology with essential user-friendly features. Their high efficiency, durable construction, flexibility in installation, and comprehensive safety measures make them an excellent choice for those seeking reliable and effective heating solutions. Whether for residential or commercial applications, these boilers truly represent the next generation of heating technology.