Planning Information

Pro 36" (914) Wall Chimney Hood

M O D E L P W C 3 6 2 4 1 8 ( R )

I N S T A L L A T I O N N O T E S

Refer to the illustrations and specifications for overall dimensions and installation specifics.

Wolf Pro wall chimney ventilation hoods are recommended for use with any Wolf cooking appliance, and should be as least as wide as the cooking surface. It is recommended that the hood overlap the cooking surface by 3" (76) on either side.

Optional 6" (152), 12" (305), 18" (457) and 24" (610) duct covers are available as a sales accessory to complete the chimney design.

Installation of all Pro wall chimney hoods should be 30" (762) to 36" (914) from the bottom of the hood to the countertop. Follow the dimensions shown in the Installation illustration.

Wolf Pro wall chimney hoods are shipped without a blower assembly. Internal, in-line or remote blower assemblies are available. Blower options also vary with the volume of air that needs to be moved and the length of the duct run. Refer to page 8 for Pro Ventilation CFM Recommendations and Blower Options.

IMPORTANT NOTE: Install this ventilation hood only with a Wolf blower.

Pro wall chimney hoods require a separate, grounded 110/120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker. Placement of the electrical supply is not critical, as long as you provide enough 120 V AC, 60 Hz power cable to make the electrical connection. Locate electrical within the shaded area shown in the Installation illustration.

You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.

Refer to the installation instructions shipped with each Wolf product for detailed specifica- tions. This information can also be found on our website, wolfappliance.com.

Dimensions in parentheses are in

millimeters unless otherwise specified.

5

Page 5
Image 5
Wolf Appliance Company PWC362418 dimensions Installation N O T E S