Installation Considerations

5

wolfappliance.com/specs

Combination Installations

Refer to the illustrations showing combination installations on pages 10–13. Also refer to installation instructions provided with the other Wolf products.

The warming drawer may be installed in combination with a Wolf built-in oven and/or microwave oven. Additional clearance between warming drawer and oven openings may be required. To allow the warming drawer trim and the oven trim to meet, a 7/8" (22) platform may be used to separate the two openings. This will act as the support platform for the oven and the anti-tip device for the warming drawer. An anti-tip block may be installed at the rear of the cabinet in place of the platform. If the warming drawer is installed above an oven, a 7/8" (22) platform is required to allow for clearance of overlaps.

The warming drawer may be installed below a Wolf cooktop or sealed burner rangetop. Allow enough room for gas and electrical connections for the cooktop.

The warming drawer may be installed next to or above another Wolf warming drawer.

Model WWD30O may be installed below a Wolf outdoor grill.

Electrical Requirements

The electrical supply should be located as shown in the illustration for your specific installation on the following pages. A separate circuit, servicing only this appliance is required.

IMPORTANT NOTE: You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.

If two warming drawers are installed side by side, they can operate from the same electrical outlet. A 30 amp circuit breaker is required for this installation.

IMPORTANT NOTE: When installed outdoors, a ground fault circuit interrupter (GFCI) is required to reduce the risk of electrical shock.

Electrical Requirements

Power Supply

120 V AC, 50/60 Hz

Circuit Breaker

15 or 20 amp

Receptacle

3-prong grounding-type

 

 