Installation Considerations 5
wolfappliance.com/specs
Combination Installations
Refer to the illustrations showing combination installations
on pages 10–13. Also refer to installation instructions
provided with the other Wolfproducts.
The warming drawer may be install ed in combination
with a Wolf built-in oven and/or microwave o ven.
Additional clearance between warming drawer and
oven openings may be required. To allow the warming
drawer trim and the oven trim to meet, a 7/8"(22)
platform may be used to separate the two openings.
This will act as the support platform for the oven and
the anti-tip device for the warming drawer.An anti-tip
block may be installed at the rear of the c abinet in
place of the platform. If the warming drawer is installed
above an oven, a 7/8"(22) platform is required to a llow
for clearance of overlaps.
The warming drawer may be install ed below a Wolf
cooktop or sealed burner rangetop. Allow enough
room for gas and electrical connect ions for the
cooktop.
The warming drawer may be install ed next to or above
another Wolf warming drawer.
Model WWD30O may be installed below a Wolf
outdoor grill.
Electrical Requirements
Power Supply 120 V AC, 50/60 Hz
Circuit Breaker 15 or 20 amp
Receptacle 3-prong grounding-type
Electrical Requirements
The electrical supply should be lo cated as shown in the
illustration for your specifi c installation on the following
pages. A separate circuit, servic ing only this appliance is
required.
IMPORTANT NOTE: You must follow all National Electrical
Code regulations. In addition, be a ware of local codes and
ordinances when installing your s ervice.
If two warming drawers are installe d side by side, they can
operate from the same electrical ou tlet. A 30 amp circuit
breaker is required for this installat ion.
IMPORTANT NOTE: When installed outdoors, a grou nd
fault circuit interrupter (GFCI ) is required to reduce the risk
of electrical shock.