Installation Considerations | 4 |
|
|
Installation Considerations
•The warming drawer must be installed with a Wolf stainless steel or integrated drawer front. Make sure you have the accessory drawer front called for in your installation. Specific installation instructions are included with the drawer front.
•For all installations, the warming drawer must be fully enclosed, top and bottom.
•The warming drawer platform must be able to support 200 lbs (90 kg). The platform must be a minimum of 1" (25) above the toe kick to allow for the warming drawer trim which overlaps 5/8" (16) on all four sides.
•Check with local utilities for electrical codes that apply in your area. Local codes vary. Installation, electrical connections and grounding must comply with applica- ble codes. In the absence of local codes, the drawer should be installed in accordance with National Electri- cal Code ANSI/NFPA
•Model WWD30O is CSA approved for outdoor installations.
TOOLS AND MATERIALS REQUIRED
•Minimum 3/4" (19) thick lumber for the solid platform that supports the warming
•Wood screws and hardware to install the platform.
•Lumber for
•Power saw.
•Level.
•Drill and 1/16" bit, 1/2" bit also for integrated drawer front application.
•Phillips screwdriver.
•2 wood screws (provided).
•Wood cleats (optional).