ELECTRICAL REQUIREMENTS

This equipment must be grounded. Verify that any existing electrical outlet and circuit you intend to plug into is actually ground- ed. Under no circumstances should the grounding pin from any three-pronged plug be removed. Serious injury may occur.

110V Operation

The Shop Fox® W1676 is prewired for 110 volts. The motor supplied with your new machine is rated at 1 H.P. and will draw approximately 14 amps. When choosing an outlet for this machine, consider using one with a 15 amp circuit break- er or fuse. Keep in mind that a circuit being used by other machines or tools at the same time will add to the electrical load being applied to the circuit. Add up the load ratings of all machines on the circuit. If this number exceeds the rating of the circuit breaker or fuse, use a different circuit.

Figure 1. Never remove grounding pin.

Figure 1A. Typical 110V 3-prong plug and outlet.

-7-

Extension Cords

When it is necessary to use an extension cord, use the following guidelines:

•Use cords rated for Hard Service (Grade S) •Never exceed a length of 100 feet

•Use cords with 14 ga. wire or bigger (12 ga., 10 ga., etc.)

•Ensure cord has a ground wire and pin •Do not use cords in need of repair

Grounding

This machine must be grounded! See Figure 1A. The electrical cord supplied with the W1676 comes with a grounding pin. Do not remove it. If your outlet does not accommodate a ground pin, have it replaced by a qualified electrician or have an appropriate adapter installed. Please note: when using an adapter, the adapter must be grounded.

An adapter with a grounding wire does not guar- antee machine will be grounded. Ground source must be verified.

Page 9
Image 9
Woodstock W1676 instruction manual Electrical Requirements, 110V Operation, Extension Cords, Grounding