Woodstock W1779 owner manual Troubleshooting

Models: W1779

1 20
Download 20 pages 12.31 Kb
Page 17
Image 17

Model W1779 18 Gauge Stapler Kit

Troubleshooting

Symptom

Possible Cause Cause

Possible Solution

Air leaking at

1. O-rings in trigger valve

1. O-rings must be replaced

trigger valve area.

housing are damaged.

& operation of safety nose

 

 

must be checked.

 

 

 

Air leaking

1. Loose screws in housing.

1. Tighten screws.

between housing

2. Damaged O-ring.

2. Replace O-ring

and hose.

3. Loose air fitting.

3. Tighten air fitting & use

 

 

teflon tape.

 

 

 

Air leaking

1. Damaged seal.

1. Replace damaged seals.

between housing

 

 

and cap.

 

 

 

 

 

Tool skips staples

1. Excessive air pressure.

1.Reduce air pressure to tool.

while discharging.

2. Air leaks.

2. Reseal and tighten screws

 

 

and fittings.

 

3. Dirt in nose.

3. Clean nose.

 

4. Dirt or damage prevents

4. Clean magazine and

 

staples from moving freely.

inspect/repair damage.

 

5. Inadequate air flow to tool.

5. Check fittings, hose,

 

 

compressor, and air

 

 

pressure.

 

6. Worn piston O-ring or lack of

6. Replace O-ring and

 

lubrication.

lubricate.

 

7. Damaged trigger valve O-

7. Replace trigger valve O-

 

rings.

rings.

 

8. Worn bumper.

8. Replace bumper.

 

9. Cap seal leaking.

9. Replace cap seal.

 

 

 

Tool runs slowly

1. Undersized air hose.

1. Use a larger hose.

or has a loss of

2. Stapler is not lubricated.

2. Lubricate stapler.

power.

3. Broken spring in cap

3. Replace spring.

 

assembly.

 

 

4. Exhaust port in cap is

4. Clean or replace damaged

 

blocked.

internal parts.

 

 

 

Fasteners

1. Staples are the wrong size.

1. Use correct staples.

frequently jam the

2. Staples are bent or dirty.

2. Use undamaged, clean

stapler.

 

staples.

 

3. Magazine or nose screws are

3. Tighten magazine.

 

loose.

 

 

4. Driver or driver guide are

4. Replace worn or damaged

 

worn or damaged.

parts.

 

 

 

Stapler does not

1. Stapler is not lubricated.

1. Follow lubricating

fire.

 

instructions.

 

2. Staple is jammed in magazine

2. Clear stapler magazine or

 

or discharge area.

discharge area.

 

3. Piston shaft is damaged.

3. Replace piston shaft.

 

4. Air pressure too low.

4. Check/increase air

 

 

pressure.

 

 

 

 

-15-

 