INSTALLATION

Battery Cable Fusing

A fuse is required by the NEC to protect the battery and cables. A UL Listed DC rated slow blow fuse must be installed in the positive

(+)battery cable, within 72 inches of the battery or within 7 inches of a positive bus or switch.

Recommended Fuse: UL Listed Class T JLLN with a DC Rating. This fuse with fuse holder is available from your dealer or Xantrex.

For Freedom 10 & 15

200 amp Fuse & Holder PN# 84-4155-00 (C/R)* 200 amp Fuse & Holder PN# 84-4158-00 (R/R)**

200 amp Fuse Only PN# 84-4157-00

For Freedom 20, 25, & 30

300 amp Fuse & Holder PN# 84-4156-00 (C/R)* 300 amp Fuse & Holder PN# 84-4154-00 (R/R)**

300 amp Fuse Only PN# 84-4151-00

*Compression / Ring Terminal ** Ring / Ring Terminal

HARDWARE STACK-UP OPTIONS

+ (red)

COMPRESSION / RING TERMINAL

EXPLODED VIEWS

 

 

 

NUT

OF FUSE ASSEMBLY

 

LOCK WASHER

RING / RING TERMINAL

 

 

FLAT WASHER

 

INVERTER

BATTERY

 

CABLE

 

CABLE

 

 

INVERTER

 

FUSE

 

CABLE

NUT

LOCK WASHER

FLAT WASHER

BATTERY

CABLE

FUSE HOLDER

WARNING

Improper stack up of hardware will cause excessive heat and fuse failure. Stack up as shown.

FUSE

FUSE HOLDER

28

Page 28
Image 28
Xantrex Technology 20, 15, 30, 25 owner manual Battery Cable Fusing, For Freedom 10