INSTALLATION OPTIONS

Installation Options

Installation options 1, 2, 3, and 4 are the most commonly used applications involving specific shorepower connections, generator power options, and AC load configurations.

Shorepower configurations: Systems with one 30 amp single phase shorepower source with optional generator

Systems with two 30 amp shorepower sources with optional generator

Systems with a 50 amp 120 volt single phase (3 wire) shorepower source with optional generator

Systems with a 50 amp 120/240 volt split phase (4 wire) shorepower source with optional generator

Inverter/charger configurations:

Single Input/Single Output Freedom Marine Model 10, 15, 20

Dual Input/Dual Output Freedom Marine Model 25 and 30

Can be connected with single in/single out mode

Can be connected with dual in/single out mode

Can be connected with dual in/dual out mode

General Guide for Fuse Size and DC Cable Size*

 

 

Nominal

Cable AWG by Length

 

 

Current

(metric)

 

 

 

 

 

 

 

 

Model

Fuse Size

DC Amps

1–3 ft.

3–6 ft.

6–10 ft.

 

 

 

 

 

 

F-10

200 ADC

100 A

2

2

1/0

 

 

 

 

 

 

F-15

200 ADC

150 A

1/0

1/0

2/0

 

 

 

 

 

 

F-20

300 ADC

200 A

2/0

2/0

3/0

 

 

 

 

 

 

F-25

300 ADC

250 A

2/0

3/0

3/0

 

 

 

 

 

 

F-30

350 ADC

300 A

3/0

3/0

4/0

 

 

 

 

 

 

*This guide is intended to provide general recommendations for fuse and cable sizing. Always consult Local and National Electrical Codes for proper fuse and cable size prior to installation.

Note: The chassis grounding wire must be no smaller than 1 gauge under that of the positive battery cable.