Operating Limits

Operating Limits

Power Output

The XPower Inverter 5000 can deliver up to 4000 W continuous and up to 5000 W for five minutes.

Input Voltage

The allowable inverter input (battery) voltage ranges are shown in the following table:

Operating Condition

Voltage Range

Comment

 

 

 

Normal

11–15 V

 

 

 

 

Optimum

12.0–13.0 V

 

Performance

 

 

 

 

 

Low Voltage Alarm

11.0 V or less

The audible low battery alarm

 

 

sounds.

 

 

 

Low Voltage

less than 10.5 V

The inverter shuts down to protect the

Shutdown

 

battery from being over-discharged.

 

 

 

High Voltage

15.5 V or more

The inverter shuts down to protect

Shutdown

 

itself from excessive input voltage.

 

 

Note: Although the inverter

 

 

incorporates over-voltage protection,

 

 

it can still be damaged if input

 

 

voltage exceeds 16 V.

 

 

 

High Voltage Alarm

15.0 V

The audible high voltage alarm

 

 

sounds.

 

 

 