Troubleshooting Reference

 

 

 

 

 

 

Table 4-1

Troubleshooting Reference

 

 

 

 

 

 

 

 

Error/Warning

 

 

 

#

Code on Display

Problem

Possible Cause

Solution

 

 

 

 

 

 

12

N/A

 

No AC output

Inverter fuse open.

Inverter fuses are not

 

 

 

voltage; there is DC

 

user-replaceable. Return the

 

 

 

input voltage

 

inverter. See the Warranty

 

 

 

indication.

 

section for return information.

 

 

 

 

GFCI outlet tripped.

If AC voltage is present on

 

 

 

 

 

one AC outlet but not on the

 

 

 

 

 

other, then the GFCI

 

 

 

 

 

protection on the outlet may

 

 

 

 

 

have tripped. Disconnect all

 

 

 

 

 

loads and push the Reset

 

 

 

 

 

button on the GFCI outlet.

 

 

 

 

 

Reconnect the load to the

 

 

 

 

 

receptacle that was tripped,

 

 

 

 

 

and if it trips again, the load or

 

 

 

 

 

its wiring is faulty and must be

 

 

 

 

 

serviced by a qualified service

 

 

 

 

 

personnel.

 

 

 

 

The inverter could have

The inverter has been

 

 

 

 

been connected with

damaged. Return the inverter.

 

 

 

 

reverse DC input

See the Warranty section for

 

 

 

 

polarity.

return information.

 

 

 

 

 

NOTE: Damage caused by

 

 

 

 

 

reverse polarity is not covered

 

 

 

 

 

by the warranty.

 

 

 

 

 

 