Measured inverter output is too low.

Possible Cause

Suggested Remedy

Astandard “average-reading” AC voltmeter has been used to measure output voltage, resulting in an apparent reading 5-15 volts too low.

The battery voltage is too low.

For accurate measurement, the XPower modified sine wave output requires a “true RMS” voltmeter for accurate measurements.

Recharge the battery.

Alarm is sounding.

Possible Cause

Suggested Remedy

 

 

Low voltage shutdown or

Shorten cables or use heavier

thermal shutdown has occurred.

cables. Recharge battery. Allow unit

 

to cool. Improve air circulation

 

around unit. Locate units in a cooler

 

environment. Reduce load if

 

continuous operation is required.

38

Page 39
Image 39
Xantrex Technology 700 PLUS, 175 PLUS, 400 PLUS manual Measured inverter output is too low, Alarm is sounding