OPERATION
GEN ON Light
The GEN ON light is on whenever the generator is running. This includes when the auxiliary generator is run manually. DEFAULT: Light OFF
GEN FAULT Light
The generator has failed to start or has stopped during AGS control. This will happen if the generator is manually stopped by a generator start/stop switch that is independent of the AGS. Cycling the ON/OFF switch will clear the fault. Check generator for normal operation.
DEFAULT: OFF
On/Off | ON/OFF MODE Switch |
Pressing the ON/OFF switch changes the status of | |
| the AGS from OFF to AUTO to AUTO QUIET mode. |
When it is off, the OFF light is illuminated.
DEFAULT: OFF mode.
AUTO Mode
In AUTO mode, the Control Module will respond to requests for generator start from a low battery condition or from an air conditioning demand.
AUTO QUIET Mode
In AUTO QUIET mode (both lights on at the same time) the Control Module will respond to requests from low battery or air conditioning because the time is outside of the
6