OPERATION

GEN ON Light

The GEN ON light is on whenever the generator is running. This includes when the auxiliary generator is run manually. DEFAULT: Light OFF

GEN FAULT Light

The generator has failed to start or has stopped during AGS control. This will happen if the generator is manually stopped by a generator start/stop switch that is independent of the AGS. Cycling the ON/OFF switch will clear the fault. Check generator for normal operation.

DEFAULT: OFF

On/Off

ON/OFF MODE Switch

Pressing the ON/OFF switch changes the status of

 

the AGS from OFF to AUTO to AUTO QUIET mode.

When it is off, the OFF light is illuminated.

DEFAULT: OFF mode.

AUTO Mode

In AUTO mode, the Control Module will respond to requests for generator start from a low battery condition or from an air conditioning demand.

AUTO QUIET Mode

In AUTO QUIET mode (both lights on at the same time) the Control Module will respond to requests from low battery or air conditioning because the time is outside of the user-set Quiet Time. In AUTO QUIET mode (AUTO light on and QUIET light blinking) the AGS will not respond to requests for low battery or thermostats starting because the Local Time is within the Quiet Time window.