Cable Installation (Step 2)

Connect the display to the controller using the serial communications cable provided. The cable is a six-conductor telephone cable with modular-type connectors (RJ-15). Although any telephone-type cable will work, the cables provided with the displays use stranded and tin-plated wire for better performance and longer life.

The following instructions are illustrated in Figure 6.

To connect the Faceplate to the C-Series controller:

1.Remove the front cover of the C-Series controller by removing the four screws on the front cover of the unit.

2.Remove the LED on the circuit board of the C-Series controller next to the RJ-15 Port just above the BATTERY POSITIVE connector. If the LED must be replaced in the future, it will operate in either orientation, except if replaced incorrectly, the color of the status LED will be reversed.

3.Insert the serial communications cable from the faceplate into the RJ-15 Port.

4.Align the faceplate on the front of the C-Series controller so that the holes for the faceplate match.

5.Secure the faceplate in place using the four screws removed in Step 1.

10

975-0123-01-01 Rev A

Page 16
Image 16
Xantrex Technology C40R/50 Remote manual Cable Installation Step, To connect the Faceplate to the C-Series controller