Mounting the Remote (Step 3)

The remote can be permanently installed in a wall or cabinet.

The unit can also be flush-mounted into a rectangular opening in a wall or surface-mounted using a double-gang, non-metallic outlet box.

To flush mount the remote, an opening must be cut in the backing material to allow room for the circuit board, wires, and connectors. Allow at least 1 ½ inch minimum clearance behind the circuit board for the connectors and wires.

Important: Use great care when cutting out the area for the circuit board from the backing material (i.e., wallboard). Ensure there is enough area left to securely hold the screws.

Minimum Clearance

Ports

Circuit Board

Faceplate

1.5" (38 mm)

Figure 8 Minimum Clearance for the Remote

14

975-0123-01-01 Rev A