Electrical Specifications

AC Power Section

Output power

 

Continuous output power

240 W

Peak output power

300 W

• AC output surge capacity

480 W

 

 

Output voltage

120 ± 10 V AC RMS

 

 

Output frequency

60 Hz ± 1 Hz

 

 

Output wave form

modified sinewave

 

 

No load current draw

<0.20 A DC

 

 

Input voltage range

10.5 to 15.5 V DC

 

 

Low battery alarm

11.0 V DC

 

 

Low battery shutdown

10.5 V DC

 

 

High battery voltage shutdown

Yes, automatic reset

 

 

Over temperature shutdown

Yes, automatic reset

 

 

Overload shutdown

Yes, automatic reset

 

 

AC output short circuit protection

Yes, automatic reset

 

 

Fuse (internal)

25 A

 

 

Operating temperature range

0–40 ºC (32–104 ºF)

 

 

Storage temperature range

0–30 ºC (32–86 ºF)

 

 

 

 

Internal Battery Charging Controller System

 

 

AC charger bulk charging current

500 mA

 

 

Peak charging voltage (nominal)

14.2 V

 

 

Charge restart voltage (nominal)

12.9 V

 

 

Float charge after full charge is completed

1 mA

(nominal)

 

 

 

AC charger input socket maximum current

2.5 A

 

 

 

42