6279 Specific Notes
Overview
This section is clarification to the existing documentation available for the 6279 system.
Timer Reset Button
This button will reset the timer value to the previous setting, NOT to the factory default setting.
Shared Settings
Many of the setting for
Can’t interrupt multi-page/set operations
When creating a collated copy set or a
Speeding up Remote Print Times
When scanning a document to a remote printer it is important to use an appropriate resolution for the application. A 600 dpi scan in full color will take significantly longer to process than a 200 or 300 dpi scan. Unless the application warrants a high resolution scan, it is recommended that
Installing and removing feature keys
The 6279 system must be in an idle state, not in a
Any Sheet page sizes
When submitting a job where the media size is set to “ANY_SHEET” all standard page sizes will be used to identify a good fitting sheet. Standard page sizes include all ANSI, ARCH, ISO A, ISO B, 30x42, 17x25, 22x36 and extended ISO sizes like 297x1189, 297x841, 420x841, 594x1189, 841x2378.,
Changing settings on Instant Accxes folders
When settings are changed on Instant Accxes folders, the folder usually needs to be
Background removal is dependant on the document
Background removal is a function of the document content and may be different depending on which side of the document is scanned first. Rotating a document which had poor background suppression results may improve the background removal.
The toner door is interlocked
There is an interlock switch on the toner door which will shut down the machine if the door is opened to prevent injury to users.
12