Other changes 13
You can follow the steps below to set the DELAY TIME using the
SCENE STORE (or SCENE TITLE EDIT) pop-up window.
1. Move the cursor to the COMMENT/MIDI EVENT section,
then click the EVENT CODE SET button.
2. Click T and numbers 0-9 on the character palette to specify
the two-digit delay time in 100 msec steps. For example, if
you wish to delay the MIDI event output from scene recall by
500 msec, enter “T05.” You do not need to enter a value if you
do not want to delay the event output.
3. Click 1, 2 (Console 1 or 2), or E (Engine) on the character
palette to configure a MIDI port to output MIDI events.
The OSCILLATOR and TALKBACK screens now feature a
CLEAR ALL button that cancels all assignments to the buses.
The DSP1D OUTPUT 6 connector can now output MONI-
TOR A/B and CUE signals. This is convenient when you use
the PM1D Manager’s remote control function for the monitor/
cue operation.
When you turn on the MONITOR/CUE OUTPUT TO #6 but-
ton in the SYSTEM CONNECTION screen, the MONITOR A/
B and CUE 1/2 signals are output to the device connected to
the DSP1D’s OUTPUT 6 connector (channels 25-32). The fol-
lowing signals are output to the specified channels:
Note
Even if you have set the output patch, when the MONITOR/
CUE OUTPUT TO #6 is turned on, the MONITOR/CUE signals
will have priority and will be output.
The MONITOR/CUE signal output to the unit is the same as the
signal output from the engine to the console. The TALKBACK
DIMMER, CUE INTERRUPT, ON/OFF, and LEVEL controls on
the console are ineffective for the signals output from the unit.
Therefore, the meter indication does not necessarily reflect the
level of the output signals. For details on the signals output from
the engine, refer to the PM1D System Block Diagram.
CLEAR ALL button added to the OSCILLATOR and TALKBACK screens
OSCILLATOR
TALKBACK
Outputting the MONITOR and CUE signals from the DSP1D
Channel number Output signal
25/26 MONITOR A L/R
27/28 MONITOR B L/R
29/30 CUE 1 L/R (Console 1 CUE signals)
31/32 CUE 2 L/R (Console 2 CUE signals)
SYSTEM CONNECTION
MONITOR / CUE OUTPUT
TO #6 button