Ground (earth) Lead

Diameter:

0.12mm (0.005 in)/ampere

EX;

10 Ampere 1.2mm (0.05 in)

 

AE00088

1

CONNECTION NOTES

 

9Avoid connecting the generator to commercial

power outlet.

9 Avoid connecting the generator in parallel with any other generator.

2

1 Correct

2Incorrect

 

 

AE00091

 

 

CONNECTION

1

 

w

 

 

Before the generator can be connected to a build-

 

 

 

 

ing’s electrical system, a licensed electrician must

 

 

install an isolation (transfer) switch in the build-

 

 

ing’s main fuse box. The switch is the connection

2

 

point for generator power and allows selection of

 

generator or main line power to the building. This

 

 

 

 

will prevent the generator from charging the main

 

 

power line (backfeeding) when the main power

 

 

supply has failed or has been turned off for line

741-090

 

repair. Backfeeding can electrocute or injure line

 

 

maintenance personnel. Also, generator and build-

 

 

 

ing electrical system damage can occur when nor-

 

 

mal operating power returns if unit is used without

 

 

an isolation switch.

 

 

 

 

AE00086

EXTENSION CORD NOTES

9When using an extension cord, its total length

should not exceed

60 meters for cross section of 1.5 mm square and

100 meters for cross section of 2.5 mm square.

9This extension cord should be protected by a tough flexible rubber sheath (IEC 245) or the equivalent to withstand mechanical stresses.

– 6 –