AE00953

Overload indicator light

 

 

The overload indicator light 1 comes on when an

 

overload of a connected electrical device is detected,

 

the inverter control unit overheats, or the AC output

 

voltage rises. The electronic breaker will then activate,

763-225

stopping power generation in order to protect the gen-

 

erator and any connected electric devices. The AC

 

pilot light (green) will go off and the overload indicator

 

light (red) will stay on, but the engine will not stop run-

 

ning.

 

When the overload indicator light comes on and power

 

generation stops, proceed as follows:

1.Turn off any connected electric devices and stop the engine.

2.Reduce the total wattage of connected electric devices within the application range.

3.Check for blockages in the cooling air inlet and around the control unit. If any blockages are found, remove.

4.After checking, restart the engine.

NOTE:

9The generator AC output automatically resets when the engine is stopped and then restarted.

9The overload indicator light may come on for a few seconds at first when using electric devices that require a large starting current, such as a compressor or a submergible pump. However, this is not a malfunction.