706-025

q

788-001

w

707-103

712-026

AE00601

STORAGE

Long term storage of your machine will require some preventive procedures to guard against deterioration.

AE01095

DRAIN THE FUEL

1.Remove the fuel tank cap. Drain the fuel from the fuel tank into an approved gasoline container using a commercially available hand siphon. Then, install the fuel tank cap.

w

9Fuel is highly flammable and poisonous. Check “SAFETY INFORMATION” (See page 4) carefully.

9Wipe up any spilled fuel immediately.

2.Remove the cover 1.

Drain fuel from the carburetor by loosening the drain screw 2 on the carburetor float chamber.

3.Turn the fuel cock knob to “OFF”.

Start the engine and leave it run until it stops. This will burn any remaining fuel in the carburetor.

AE00621

ENGINE

1.Remove the spark plug, pour about one table- spoon of SAE 10W30 or 20W40 motor oil into the spark plug hole and reinstall the spark plug. Recoil start the engine by turning over several times (with ignition off) to coat the cylinder walls with oil.

2.Pull the recoil starter until you feel compression. Then stop pulling. (This prevents the cylinder and valves from rusting).

3.Clean exterior of the generator and apply a rust inhibitor.

4.Store the generator in a dry, well-ventilated place, with the cover placed over it.

5.The generator must remain in a vertical position when stored, carried or operated.

– 30 –