14
add-
3.2.5.3 All Notes Off
Note off is executed. However, if Hold 1 is on, the sound will not stop until a Hold 1
= off message is received.
3.2.5.4 Omni Off
Omni Off is executed. (Rest is the same as in “All Notes Off” above.)
3.2.5.5 Omni On
Since the MU5 has no such function, Omni On is not executed. (Rest is the same as
in “All Notes Off” above.)
3.2.5.6 Mono
Same as in “All Sounds Off” above. If the third byte is 0 – 16 (Mono value), the
allocated channels are set to Mode 4 (m = 1)*.
* See the MIDI Implementation Chart on page add-24.
3.2.5.7 Poly
Same as in “All Sounds Off” above. If the third byte is 0 – 16 (Mono value), the
allocated channels are set to Mode 3*.
* See the MIDI Implementation Chart on page add-24.
3.2.6 RPN (Registered Parameter Number)
The RPN MSB and RPN LSB must be sent first for the specific control parameter,
followed by the data entry values. The MU5 receives and responds to the following
RPN:
RPN Data Entry
MSB LSB MSB LSB
$00 $00 $mm -- Pitch bend sensitivity
mm : $00 $18 (0 24 semitones)
-- : Not used
Range is two octaves, selectable in one semitone
steps. When power is turned on, this is set to two
semitones.
$00 $01 $mm $11 Master fine tuning
(mm,11) : ($00,$00) ($40,$00) ($7F,$7F)
(-8192x100/8192) 0 (+8192x100/8192 cents)
$00 $02 $mm -- Master coarse tuning
mm : $28 $40 $58 (-24 0 +24 semitones)
-- : Not used
$7F $7F $-- -- RPN Null
-- : Not used
RPN or NRPN are not set. Internal data does not
change.
The values set by using RPN are not reset, even when program change messages are
received. If the parameter has a relative value, the actual range of adjustment may
occasionally be narrower than the specified range (depending on the program
number).