MIDI Mode
8
Setting the MIDI Receive Channel
By default, the REV100 is set to receive MIDI on all channels (OMNI mode). You can change this default with the following pro-
cedure:
1.
Press and hold the MIDI key as you switch on the power to the REV100.
The 7-segment LED will display “ ” and the current MIDI channel number alternately.
2.
Select another MIDI channel number by pressing the or keys.
You can select “ ” (OMNI), “ ” to “ ”, or “ ” (OFF).
3.
Press the MIDI key again to return to normal operational mode.
Real-time Parameter Change
You can send MIDI Control Change messages to the REV100. Some of these messages perform the same function as the front
panel Edit controls, others allow you access to additional parameters:
Effect Type Parameter Name Controller Number
REVERB
Pre Delay 20
Reverb Time 21
Effect Level 22
High Damp 23
Filter Type (LPF/HPF) 24
Cut-off Frequency 25
STEREO REVERB
Pre Delay 20
Reverb Time 21
Effect Level 22
High Damp 23
GATE REVERB
Pre Delay 20
Gate Level 21
Effect Level 22
Reverb Time 23
High Damp 24
Release Time 25
Filter Type (LPF/HPF) 26
Cut-off Frequency 27
DELAY
Delay Time 20
Feedback Level 21
Effect Level 22
High Damp 23
Filter Type (LPF/HPF) 24
Cut-off Frequency 25
DELAY/REVERB
Delay Time 20
Feedback Level 21
Reverb Level 22
Reverb Time 23
Reverb High Damp 24
Delay High Damp 25
Filter Type (LPF/HPF) 26
Cut-off Frequency 27