| E |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| EMU01191 | ||
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| LOW OIL LEVEL WARNING | ||
|
| q |
|
|
|
|
|
|
|
| ACTIVATES | ||
|
|
|
|
|
|
|
|
|
| If the oil level is allowed to drop too low, | |||
|
|
|
|
|
|
|
|
|
|
| the red segment will appear on the oil | ||
|
|
|
|
|
|
|
|
|
|
| level indicator, the buzzer will sound, and | ||
|
|
|
|
|
|
|
|
|
|
| engine speed will be limited to about | ||
|
|
|
|
|
|
|
|
|
|
| 2,000 r/min. If this happens, a reserve | ||
|
|
|
|
|
|
|
|
|
|
| amount of oil can be pumped from the | ||
|
|
|
|
|
| 218013 |
|
| |||||
|
|
|
|
|
|
| remote oil tank 3 to the engine oil tank 2 | ||||||
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| using the emergency switch 1. | ||
|
|
|
|
|
|
|
|
|
|
| w | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Be sure to stop the engine before per- | ||
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| forming this procedure. | ||
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| cC | ||
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| 8If the emergency switch is held up too | ||
|
|
|
|
|
|
|
|
|
|
| |||
| w | e | 905013 |
|
| long, too much oil will be pumped into | |||||||
|
|
| the engine tank, overflowing it. Release | ||||||||||
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| the switch when oil reaches the upper | ||
|
|
|
|
|
|
|
|
|
|
| level line on the engine oil tank. | ||
|
|
|
|
|
|
|
|
|
|
| 8Do not use this emergency procedure | ||
|
|
|
|
|
|
|
|
|
|
| unless the oil level warning lamps are | ||
|
|
|
|
|
|
|
|
|
|
| installed and working. | ||
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| 1) Remove the top cowling. | ||
|
|
|
|
|
|
|
|
|
|
| 2) Turn the main switch to the “ON” | ||
|
|
|
|
|
|
|
|
|
|
| position. | ||
|
|
|
|
|
|
|
|
|
|
| 3) Lift the emergency switch to pump | ||
|
|
|
|
|
|
|
|
|
|
| reserve oil in remote oil tank into the | ||
|
|
|
|
|
|
|
|
|
|
| engine oil tank. | ||
|
|
|
|
|
|
|
|
|
|
| 4) After using the emergency switch, | ||
|
|
|
|
|
|
|
|
|
|
| turn off the main switch, then turn it | ||
|
|
|
|
|
|
|
|
|
|
| back on. This resets the warning sys- | ||
|
|
|
|
|
|
|
|
|
|
| tem for normal operation. Yellow seg- | ||
|
|
|
|
|
|
|
|
|
|
| ment will remain appearing on oil | ||
|
|
|
|
|
|
|
|
|
|
| level indicator at this time. | ||
|
|
|
|
|
|
|
|
|
|
| 5) Start the engine and return to the | ||
|
|
|
|
|
|
|
|
|
|
| nearest port for more oil. | ||
|
|
|
|
|
|
|
|
|
|
|
|