6)Turn the main switch to “ON”.

NOTE:

In case of dual-engine operation, when the main switch is turned on, the buzzer operates for a few seconds and stops automatically. Should either of the dual engines stall, the buzzer operates.

OFF ON START

701022

ON

OFF START

703045

EMU00949

Electric Start Model

7)Turn the main switch to “START”, and hold it for a maximum of 5 sec- onds.

8)Immediately after the engine starts, release the main switch to return it to “ON”.

cC

8 Do not turn the main switch to“START” when the engine is running.

8 Do not keep the starter-motor turning for more than 5 seconds. The battery will rapidly become exhausted and it will be impossible for it to start the engine. If the engine does not start within 5 seconds, return the main switch to “ON”, wait 10 seconds, and then crank the engine again.