PRE-INSTALLATION CHECKS

PRE-INSTALLATION CHECKS

1. FLUES

MODEL:

Exmoor YM-W9001FL / YM-W9001LC / YM-W9001ERFL / YMW9001ERLC

Exe YM-W9101FL / YM-W9101LC / YM-W9101ERFL / YMW9101ERLC YM-W9102FL / YM-W9102LC / YM-W9102ERFL / YM-W9102ERLC Devon YM-W9201FL / YM-W9201LC / YM-W9201HC / YM-W9201ERFL /

YM-W9201ERLC / YM-W9201ERHC / YM-W9202FL / YM-W9202LC / YM-W9202HC / YM-W9202ERFL / YM-W9202ERLC / YM-W9202ERHC

County YM-W9301FL / YM-W9301LC / YM-W9301HC / YM-W9302FL/ YM-W9302LC / YM-W9302HC

 

Without flue liner Round

mm

 

(diameter)

inch

 

 

 

Without flue liner system

mm

 

Square (diameter)

inch

Flue/Chimney Size

 

With liner or Factory made

mm

 

 

system (diameter)

inch

 

installed in accordance with manufacturer's instructions

 

 

Flue/Chimney

All products

metre

feet

(*minimum height)

 

 

 

 

Exmoor

Exe

Devon

County

150

150

150

150

6

 

6

6

 

6

 

135

135

135

135

51/

2

51/

51/

2

51/

2

 

2

 

 

†150

150

150

150

†6

6

6

 

6

 

4.5

4.5

4.5

4.5

15

15

15

15

*When measured from the top of the stove to the top of the flue, with no horizontal sections and a maximum of 4 bends with angles of less than 45o

†May be 125mm (5") if only burning low volatiles (smokeless) fuels approved for use in Smoke Control Areas.

See web sit http://uksmokecontrolareas.co.uk for more information about approved fuel

2. ADDITIONAL VENTILATION

2.1Additional ventilation is required to comply with the requirements of the Building Regulations. This must be provided using a permanently open air vent, of the size listed, which is positioned so that it is not liable to be blocked both inside and outside the building.

2.2Extractor fans or cooker hoods must not be placed in the same room or space as this can cause the appliance to emit fumes into the room.

2.3If any of these checks reveal problems do not proceed with the fitting of the appliance until they have been rectified.

MODEL:

 

 

 

 

 

 

Exmoor YM-W9001FL / YM-W9001LC / YM-W9001ERFL / YMW9001ERLC

 

 

 

 

Exe

YM-W9101FL / YM-W9101LC / YM-W9101ERFL / YMW9101ERLC

Exmoor

 

Devon

County

 

YM-W9102FL / YM-W9102LC / YM-W9102ERFL / YM-W9102ERLC

Exe

Devon YM-W9201FL / YM-W9201LC / YM-W9201HC / YM-W9201ERFL /

 

YM-W9201ERLC / YM-W9201ERHC / YM-W9202FL / YM-W9202LC /

 

YM-W9202HC / YM-W9202ERFL / YM-W9202ERLC / YM-W9202ERHC

 

 

 

 

 

County YM-W9301FL / YM-W9301LC / YM-W9301HC / YM-W9302FL /

 

 

 

 

 

YM-W9302LC / YM-W9302HC

 

 

 

 

 

 

 

 

 

 

 

 

 

mm2

0

0

2200

4400

 

Additional Ventilation

cm2

0

0

22

44

 

in2

0

0

3.41

6.82

 

 