USER INSTRUCTIONS
AIRWASH & PRIMARY AIR CONTROLS
1.14Use a gloved hand to operate air controls.
The opposite end of the door tool can be used to operate Airwash controls.
Airwash Control | |
Open | Close |
Open
Open
1 Door | PR7522 |
| 2 Door | PR7523 |
Airwash Control
Primary Air Control PR7518
Single Door
Primary Control
Open
Airwash Control
Primary Air Control PR7519
Two Door
Primary Control
Open Close Open
DO NOT OPEN THE DOOR WITH BARE HANDS
1.16 To close the door follow the process in reverse.
WARNING
Properly installed, operated and maintained this appliance will not emit fumes into the room.
Occasional fumes from
Persistent fume emission is potentially dangerous and must not be tolerated.
SECONDARY AIR CONTROLS
Secondary Air Control PR7520 |
| Secondary Air Control PR7521 |
|
|
|
Single & Two Door
Secondary Control
Close
Open
DOOR HANDLE
1.15To Open and Close the door:
•Drop door tool over knob to fit
•Rotate 1/2 turn
•Rotate 1/2 turn clockwise to close
•Lift up door tool to remove
If fume emission does persist:
•Open doors and windows to ventilate the room
•Leave the room
•Allow fire to burn out or safely dispose of fuel from the appliance
•Check for chimney blockage and clean if required
•Do not attempt to relight until the cause of the emission has been identified and corrected
If necessary seek expert advice.
•All open flued appliances can be affected by temporary atmospheric conditions which may allow fumes to enter the house. Because of this it is recommended that an electronic carbon monoxide detector conforming to BSEN50291 be fitted and maintained.
2.USING THE Appliance FOR THE FIRST TIME
2.1To allow the appliance to settle and fixing glues and paint to fully cure:
•Operate the appliance at a low output for first few days
2.2Do not touch the paint during the first period of use.
2.3During this time the appliance may give off some unpleasant odours:
•Keep the room well ventilated to avoid a