7. ASH REMOVAL

USER INSTRUCTIONS

7. ASH REMOVAL

Do not allow ash to build up in the appliance as it will not burn properly and may cause damage.

7.1Wood

Open doors and using gloves remove ashpan with the tool provided (see Diagram 10).

Remove ash and place into a Yeoman Ash Caddy (Yeoman Part No. 4227) or other suitable container.

Do not place hot ash in any container made from plastic or any other combustible material.

De-ash at least once a week or when ashpan is full.

10

Ashpan

PR9033

7.2Multi-fuel:

De-ash the appliance before filling with new fuel. Do not allow ash to build up on the underside of the grate as this can cause premature failure.

Riddle (see Diagram 11).

11

Riddling

Handle

PR9035

Remove ash and place into a Yeoman Ash Caddy (Yeoman Part No. 4227) or other suitable container.

Do not place hot ash in any container made from plastic or any other combustible material.

De-ash at least once a week or when ashpan is full.

8.EXTENDED burning

8.1It is possible to get the appliance to burn for extended periods of time. In order to do this:

De-ash prior to final refuelling.

Set air controls to low combustion settings.

This will gradually blacken the glass but it will clear when operated at a high temperature for a short period.

Use smokeless fuel or small, thick logs.

9.OVER-FIRING

9.1Do not over-fill with fuel or run at high temperatures for long periods or over-firing can occur. If the flue pipe, flue collar or top plate glow red the appliance is over-firing. Close the air controls to reduce the temperature.

9.2Over-firing can cause permanent damage to the appliance and invalidate the product warranty.

Warning: Do not operate the appliance with the Primary Air Control open for long periods of time as this could cause over- firing and may cause permanent damage.

10.Chimney fire

10.1If a chimney fire occurs:

Shut all air controls immediately.

Evacuate the building.

Call the fire brigade.

Do not re-enter the building until it is confirmed safe.

10.2Do not use the appliance after a chimney fire until:

a)It has been inspected by a registered installer* who has confirmed the appliance is safe to use.

b)The chimney system has been inspected and swept by a chimney sweep, confirming the system is structurally sound and free from obstruction**.

c)It is repaired as required before re-use. Use only genuine Yeoman replacement parts to keep your appliance in safe, efficient working order.

*Registered on the Competent Persons Scheme (GB only)/ INFO (Republic of Ireland only) see page 25 for details.

**This should be done by a HETAS Approved Chimney Sweep (UK only)/INFO registered (Republic of Ireland only) see page 26, who will issue you with a certificate.