INSTALLATION INSTRUCTIONS
1.5Reposition clamps by hand through the flue opening and tighten using a 13A/F spanner. Check the clamps are against the throat forming lintel as shown in Diagram 3.
3 |
|
|
|
| Throat |
|
|
| ø 16mm |
| forming lintel |
| |
|
|
|
|
| ||
|
|
|
|
| ||
|
| Rope seal |
|
|
| |
|
| Clamp |
| Milner | ||
|
|
| brick | |||
|
|
|
|
| ||
| Reach through door |
|
|
| ||
| and up and out |
|
|
|
| |
|
|
|
|
| ||
| of flue opening to |
|
|
| ||
| adjust clamps |
|
|
| ||
|
|
|
|
| PR9039 | |
|
|
|
|
|
|
|
1.6Check the ø16mm rope seal is still in the correct position. The appliance must be sealed against the face of the chimney breast / fire surround and at the hearth to the base of the appliance. This seal must be made
1.7Drill 2 appropriately placed ø10mm holes in the Milner hearth. Secure the stove to the hearth via the holes shown in Diagram 4 using metal wall plugs and bolts.
4
Attach stove to hearth via holes in floor of stove
PR9034
1.8Refit all internal components.
2.REMOVAL OF THE door
2.1To remove the door:
4 Bolts | PR7084 |
3.REMOVAL OF THE LOG GUARD
3.1To remove the log guard:
Do not use appliance without the log guard in position.
4.REMOVAL OF THE baffle
4.1The appliance is fitted with a baffle in the top of the firebox to maintain efficient combustion.
4.2Allow the appliance to cool fully before removing baffle system.
5
Baffle
PR9040
4.3Remove the log guard from the appliance to give access to the firebox.
20