York 60, B3CH 036, B5CH 036, B6CH 048 warranty COOLING CAPACITIES - 4 TON BCH048

Models: B6CH 048 B5CH 036 B3CH 036 48 60

1 24
Download 24 pages 35.6 Kb
Page 5
Image 5
COOLING CAPACITIES - 4 TON (BCH048)

036-21564-002-A-0404

COOLING CAPACITIES - 4 TON (BCH048)

Air On

 

 

 

 

 

 

Temperature of Air on Outdoor Coil

 

 

 

 

 

 

 

Indoor

 

 

 

85 °F

 

 

 

 

 

 

 

 

 

95 °F

 

 

 

 

Coil

 

Total

Power

 

Sensible Capacity1, MBH

 

Total

Power

 

 

Sensible Capacity1, MBH

 

CFM

 

WB

Cap.1

Input2

 

Entering Dry Bulb, °F

 

Cap.1

Input2

 

 

Entering Dry Bulb, °F

 

 

°F

MBH

KW

86

83

80

77

 

74

71

68

MBH

KW

 

86

83

80

77

74

71

68

 

 

 

 

 

 

72

56

4.1

42

36

31

26

 

-

-

-

53

4.5

 

40

35

29

24

-

-

-

2000

 

67

53

4.0

48

47

41

36

 

30

25

-

51

4.4

 

46

45

41

35

30

24

-

 

62

49

4.0

49

49

48

44

 

38

33

28

46

4.3

 

46

46

45

41

35

30

24

 

 

 

 

 

 

57

49

3.9

49

49

49

44

 

38

33

28

46

4.3

 

46

46

46

41

35

30

24

 

 

72

55

4.0

40

35

30

25

 

-

-

-

53

4.4

 

38

33

28

23

-

-

-

1800

 

67

52

4.0

47

44

39

34

 

29

24

-

51

4.4

 

44

44

39

34

29

24

-

 

62

48

3.9

48

48

47

43

 

38

33

28

47

4.3

 

47

47

45

40

36

31

26

 

 

 

 

 

 

57

48

3.9

48

48

48

43

 

38

33

28

45

4.2

 

45

45

45

40

35

30

25

 

 

72

53

4.0

37

33

28

24

 

-

-

-

52

4.4

 

36

32

27

23

-

-

-

1600

 

67

51

4.0

46

42

37

33

 

28

24

-

50

4.3

 

44

43

38

34

29

25

-

 

62

47

3.9

47

47

46

41

 

37

32

28

45

4.2

 

45

45

44

40

36

31

27

 

 

 

 

 

 

57

47

3.9

47

47

47

42

 

38

33

29

44

4.1

 

44

44

44

40

36

31

27

 

 

72

52

4.0

34

30

26

22

 

-

-

-

49

4.3

 

33

29

25

21

-

-

-

1400

 

67

49

3.9

42

38

34

30

 

26

22

-

47

4.2

 

42

38

34

30

26

22

-

 

62

46

3.8

46

45

42

38

 

34

30

26

43

4.1

 

43

42

40

36

32

28

24

 

 

 

 

 

 

57

45

3.8

45

45

43

39

 

35

31

27

42

4.1

 

42

42

40

36

32

28

24

 

 

72

50

3.9

31

27

24

20

 

-

-

-

47

4.2

 

29

25

22

18

-

-

-

1200

 

67

47

3.9

38

35

31

28

 

24

21

-

45

4.2

 

37

34

30

27

23

20

-

 

62

44

3.8

44

42

39

35

 

32

28

25

40

4.1

 

40

39

36

32

29

25

22

 

 

 

 

 

 

57

44

3.7

44

43

39

36

 

32

29

25

40

4.0

 

40

39

36

32

29

25

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air On

 

 

 

 

 

 

Temperature of Air on Outdoor Coil

 

 

 

 

 

 

 

Indoor

 

 

 

105 °F

 

 

 

 

 

 

 

 

 

115 °F

 

 

 

 

Coil

 

Total

Power

 

Sensible Capacity1, MBH

 

Total

Power

 

 

Sensible Capacity1, MBH

 

CFM

 

WB

Cap.1

Input2

 

Entering Dry Bulb, °F

 

Cap.1

Input2

 

 

Entering Dry Bulb, °F

 

 

°F

MBH

KW

86

83

80

77

 

74

71

68

MBH

KW

 

86

83

80

77

74

71

68

 

 

 

 

 

 

72

51

4.9

40

35

29

24

 

-

-

-

49

5.2

 

39

34

29

23

-

-

-

2000

 

67

46

4.7

42

42

39

34

 

28

23

-

41

5.0

 

40

40

37

32

26

21

-

 

62

43

4.6

43

43

42

37

 

32

27

21

40

4.9

 

40

40

39

34

29

23

18

 

 

 

 

 

 

57

43

4.6

43

43

43

38

 

32

28

22

40

4.8

 

40

40

40

34

30

24

19

 

 

72

50

4.8

38

33

28

23

 

-

-

-

47

5.1

 

37

32

27

22

-

-

-

1800

 

67

45

4.7

41

41

37

32

 

27

22

-

40

4.9

 

37

36

35

30

25

20

-

 

62

42

4.6

42

42

41

37

 

32

27

22

39

4.8

 

39

39

37

34

29

24

19

 

 

 

 

 

 

57

42

4.5

42

42

42

37

 

33

27

23

38

4.7

 

38

38

38

33

30

25

20

 

 

72

49

4.8

35

31

26

22

 

-

-

-

46

5.1

 

34

29

25

20

-

-

-

1600

 

67

44

4.6

40

40

35

31

 

26

22

-

39

4.9

 

36

36

32

28

23

19

-

 

62

41

4.5

41

41

40

35

 

32

27

23

37

4.7

 

37

37

36

33

28

24

19

 

 

 

 

 

 

57

41

4.4

41

41

41

36

 

32

28

23

37

4.7

 

37

37

37

34

28

25

20

 

 

72

47

4.7

32

28

24

20

 

-

-

-

44

5.0

 

31

27

23

19

-

-

-

1400

 

67

42

4.5

38

36

32

28

 

24

20

-

37

4.8

 

36

34

30

26

21

17

-

 

62

39

4.4

39

38

37

33

 

28

25

20

36

4.7

 

36

35

34

30

26

22

18

 

 

 

 

 

 

57

39

4.4

39

39

37

33

 

29

25

21

36

4.6

 

36

36

34

31

26

23

19

 

 

72

44

4.6

28

25

21

18

 

-

-

-

42

4.9

 

28

24

21

17

-

-

-

1200

 

67

40

4.5

36

32

29

25

 

22

18

-

36

4.7

 

34

31

27

24

20

17

-

 

62

38

4.4

38

36

34

29

 

27

22

20

35

4.6

 

35

34

30

28

24

20

17

 

 

 

 

 

 

57

37

4.3

37

37

34

30

 

27

23

20

35

4.6

 

35

35

31

29

24

21

18

1These capacities are gross ratings. For net capacity, determine the KW of the supply air blower motor from the Blower Performance Table, multiply this value by 3.415 MBH / KW to determine the motor heat, and deduct this heat from the gross capacity of the unit.

2These ratings include the compressor and the outdoor fan motors but not the supply air blower motor. The total outdoor fan motor power input is 0.35 KW. Refer to the Blower Performance Table for the KW of the supply air blower motor.

NOMINAL RATING

ALL SENSIBLE CAPACITY

Unitary Products Group

5

Page 5
Image 5
York 60, B3CH 036, B5CH 036, B6CH 048 warranty COOLING CAPACITIES - 4 TON BCH048

FAQ

What type of cooling capacities are provided in the York Air Conditioner manual?

The manual includes gross ratings for the cooling capacities of specific models and provides instructions for calculating net capacity.

Where can I find information on determining the net capacity for York Air Conditioner models?

The manual provides instructions on determining net capacity by calculating the KW of the supply air blower motor and 3.415 MBH / KW to determine the motor heat.

What is included in the power ratings for the outdoor fan motors in the manual?

The manual includes power ratings for the compressor and outdoor fan motors, but not the supply air blower motor. The total outdoor fan motor power input is 0.35 KW.