036-21564-002-A-0404

SUPPLY AIR BLOWER PERFORMANCE - BCH036 & 048 with Belt-Drive

BCH036 - SIDE DUCT APPLICATIONS (230/460/575 VOLTS)

MODEL

AIR FLOW

 

 

 

 

Available External Static Pressure - IWG*

 

 

 

 

0.20

0.30

0.40

0.50

0.60

0.70

0.80

BCH

CFM

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

 

 

 

2000

843

860

880

925

919

1005

956

1065

993

1145

1030

1195

1067

1235

 

1900

817

775

854

850

893

920

930

995

970

1065

1008

1125

1046

1170

 

1800

790

700

828

760

867

840

906

905

944

980

985

1040

1025

1100

 

1700

-

-

802

670

840

745

881

815

920

900

961

970

1001

1030

036

1600

-

-

-

-

818

665

858

740

898

820

940

890

980

950

 

1500

-

-

-

-

-

-

842

695

882

755

922

835

962

895

 

1400

-

-

-

-

-

-

833

650

867

705

904

765

942

820

 

1300

-

-

-

-

-

-

-

-

858

665

893

725

932

785

 

1200

-

-

-

-

-

-

-

-

847

640

880

680

916

730

 

 

 

 

 

 

 

 

 

 

 

MODEL

AIR FLOW

 

 

 

 

Available External Static Pressure - IWG*

 

 

 

 

0.90

1.00

1.10

1.20

1.30

1.40

1.50

BCH

CFM

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

 

 

 

2000

1103

1270

-

-

-

-

-

-

-

-

-

-

-

-

 

1900

1085

1210

-

-

-

-

-

-

-

-

-

-

-

-

 

1800

1064

1145

1102

1180

-

-

-

-

-

-

-

-

-

-

 

1700

1040

1075

1081

1115

1121

1140

-

-

-

-

-

-

-

-

036

1600

1020

1005

1060

1050

1100

1085

-

-

-

-

-

-

-

-

 

1500

1003

945

1044

995

1086

1035

-

-

-

-

-

-

-

-

 

1400

982

880

1024

920

1067

965

1107

1000

-

-

-

-

-

-

 

1300

970

835

1010

870

1053

920

1099

960

-

-

-

-

-

-

 

1200

953

780

992

815

1034

855

1080

905

-

-

-

-

-

-

NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0.95.

*INCLUDES ALLOWANCES FOR A WET INDOOR COIL AND 1" FILTERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN HEAT PUMP UNITS WITH SIDE DUCT AIRFLOWS.

BCH048 - SIDE DUCT APPLICATIONS (230/460/575 VOLTS)

MODEL

AIR FLOW

 

 

 

 

Available External Static Pressure - IWG*

 

 

 

 

0.20

0.30

0.40

0.50

0.60

0.70

0.80

BCH

CFM

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

 

 

 

2000

843

860

880

925

919

1005

956

1065

993

1145

1030

1195

1067

1235

 

1900

817

775

854

850

893

920

930

995

970

1065

1008

1125

1046

1170

 

1800

790

700

828

760

867

840

906

905

944

980

985

1040

1025

1100

 

1700

-

-

802

670

840

745

881

815

920

900

961

970

1001

1030

048

1600

-

-

-

-

818

665

858

740

898

820

940

890

980

950

 

1500

-

-

-

-

-

-

842

695

882

755

922

835

962

895

 

1400

-

-

-

-

-

-

833

650

867

705

904

765

942

820

 

1300

-

-

-

-

-

-

-

-

858

665

893

725

932

785

 

1200

-

-

-

-

-

-

-

-

847

640

880

680

916

730

 

 

 

 

 

 

 

 

 

 

 

MODEL

AIR FLOW

 

 

 

 

Available External Static Pressure - IWG*

 

 

 

 

0.90

1.00

1.10

1.20

1.30

1.40

1.50

BCH

CFM

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

 

 

 

2000

1103

1270

-

-

-

-

-

-

-

-

-

-

-

-

 

1900

1085

1210

-

-

-

-

-

-

-

-

-

-

-

-

 

1800

1064

1145

1102

1180

-

-

-

-

-

-

-

-

-

-

 

1700

1040

1075

1081

1115

1121

1140

-

-

-

-

-

-

-

-

048

1600

1020

1005

1060

1050

1100

1085

-

-

-

-

-

-

-

-

 

1500

1003

945

1044

995

1086

1035

-

-

-

-

-

-

-

-

 

1400

982

880

1024

920

1067

965

1107

1000

-

-

-

-

-

-

 

1300

970

835

1010

870

1053

920

1099

960

-

-

-

-

-

-

 

1200

953

780

992

815

1034

855

1080

905

-

-

-

-

-

-

NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0.95.

*INCLUDES ALLOWANCES FOR A WET INDOOR COIL AND 1" FILTERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN HEAT PUMP UNITS WITH SIDE DUCT AIRFLOWS.

8

Unitary Products Group

Page 8
Image 8
York B5CH 036, 60, B3CH 036, B6CH 048 warranty Model AIR Flow, Bch Cfm Rpm

B6CH 048, B5CH 036, B3CH 036, 48, 60 specifications

York 36, 48, and 60 are three distinct models from the York line of heating, ventilation, and air conditioning (HVAC) systems, specifically designed to meet various commercial and residential needs. Each model fits specific sizing and efficiency requirements while employing advanced technologies to enhance performance.

The York 36 model is ideal for smaller spaces or residential applications. This unit boasts a compact design that integrates seamlessly into tight locations while offering substantial energy efficiency. With a cooling capacity of approximately 36,000 BTU, it’s suitable for apartments or small commercial areas. The use of scroll compressors in this model contributes to reliable operation and quieter performance. Additionally, it utilizes environmentally friendly refrigerants that comply with modern environmental regulations, making it a sustainable choice.

The York 48 model steps up its capabilities for larger residential and commercial buildings. It provides ample cooling capacity at around 48,000 BTU, accommodating medium-sized spaces effectively. One of the standout features is its two-stage cooling technology, which allows for consistent temperature control without excessive energy consumption. This model is equipped with variable speed blowers that optimize airflow, ensuring a comfortable indoor environment even during peak summer months. The York 48 is also engineered with advanced diagnostics, allowing technicians to identify and resolve issues quickly, further enhancing reliability.

Finally, the York 60 model caters to extensive commercial applications with its impressive cooling capacity of approximately 60,000 BTU. This unit excels in large offices, retail spaces, and industrial settings. It employs advanced inverter technology, which adjusts compressor speed based on demand, leading to remarkable energy efficiency and significant cost savings in long-term operation. The York 60 also features robust insulation and weather-tight cabinet design to minimize energy loss. Additionally, its user-friendly interface allows for easy control and monitoring, ensuring optimal performance.

All three York models come equipped with state-of-the-art filters and air purifiers, improving indoor air quality by effectively reducing allergens and pollutants. With a focus on durability, energy efficiency, and advanced technology, York 36, 48, and 60 units represent versatile solutions for their respective applications, demonstrating York's commitment to innovation and sustainability in HVAC systems. Whether for a small apartment or a large commercial space, these units offer reliable comfort and performance tailored to specific needs.