York AHE18 THRU 60 warranty Air Flow, AIR FLOW DATA - 60 Hz MODELS - 208 VOLT

Models: AHE18 THRU 60

1 14
Download 14 pages 1.27 Kb
Page 12
Image 12
AIR FLOW

680210-YTG-B-0311

AIR FLOW

AIR FLOW DATA - 60 Hz MODELS - 208 VOLT

Models

Blower

 

 

CFM1 @ External Static Pressure - IWC

 

 

Motor Speed

 

 

 

 

 

 

 

 

0.10

0.20

0.30

0.40

0.50

0.60

0.70

 

 

 

208 Volt

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High #5

1074

1029

999

954

911

865

812

 

Med High #4

895

846

802

759

701

630

526

AHE18B3XH21

Med #3

663

610

556

482

334

219

173

 

Med Low #2

630

466

346

196

170

67

23

 

Low #1

630

466

346

196

170

67

23

 

High #5

1147

1107

1076

1040

992

942

861

 

Med High #4

1009

974

941

903

859

811

762

AHE24B3XH21

Med #3

826

785

744

690

639

566

501

 

Med Low #2

654

590

556

479

419

307

251

 

Low #1

580

491

425

317

224

189

73

 

High #5

1147

1107

1076

1040

992

942

861

 

Med High #4

1009

974

941

903

859

811

762

AHE30B3XH21

Med #3

826

785

744

690

639

566

501

 

Med Low #2

654

590

556

479

419

307

251

 

Low #1

580

491

425

317

224

189

73

 

High #5

1473

1417

1361

1304

1241

1171

1109

 

Med High #4

1257

1204

1138

1076

1000

928

856

AHE36C3XH21

Med #3

1069

997

912

831

772

697

617

 

Med Low #2

994

800

705

621

554

488

432

 

Low #1

904

692

411

329

256

152

NA

 

High #5

1619

1577

1531

1484

1428

1372

1307

 

Med High #4

1434

1391

1346

1292

1235

1164

1054

AHE42D3XH21

Med #3

1243

1192

1135

1073

978

882

778

 

Med Low #2

1141

1027

952

842

724

572

559

 

Low #1

1025

851

465

418

253

208

123

 

High #5

1847

1812

1775

1725

1684

1645

1600

 

Med High #4

1675

1640

1597

1561

1522

1479

1421

AHE48D3XH21

Med #3

1436

1394

1349

1301

1246

1182

1095

 

Med Low #2

1250

1211

1157

1100

1013

924

854

 

Low #1

1151

1029

965

857

779

720

639

 

High #5

2083

2042

2002

1959

1921

1875

1829

 

Med High #4

1893

1856

1815

1776

1728

1688

1639

AHE60D3XH21

Med #3

1642

1609

1564

1512

1467

1416

1340

 

Med Low #2

1443

1401

1360

1307

1242

1160

1062

 

Low #1

1259

1198

1140

1067

972

900

797

1. Dry coil conditions only, tested without filters.

Air handler units are CSA listed to UL 1995/CSA C22.2 236-05 up to 0.30" w.c. external static pressure, including air filter, wet coil, and largest kW size heater, unless otherwise noted.