York AHE18 THRU 60 Johnson Controls Unitary Products, Min. Circuit Ampacity, 75C Wire Size - AWG

Models: AHE18 THRU 60

1 14
Download 14 pages 1.27 Kb
Page 7
Image 7
Min. Circuit Ampacity

 

 

 

 

 

 

 

680210-YTG-B-0311

ELECTRICAL DATA - (FOR SINGLE SOURCE POWER SUPPLY) - COPPER WIRE - 208/230-1-60

 

 

 

 

 

 

 

 

 

 

 

 

Heater

Heater

 

 

Field Wiring

 

 

 

 

 

 

 

 

 

Models

Amps

Min. Circuit Ampacity

Max. O.C.P.1 Amps/Type

75°C Wire Size - AWG

Models*

 

240V

 

 

 

 

 

 

 

 

208V

230V

208V

230V

208V

230V

 

 

 

 

 

 

 

 

 

 

 

 

 

6HK*6500206

10.0

14.33

15.48

15

20

12

12

AHE18B3XH21

6HK*6500506

20.0

25.17

27.46

30

30

10

10

6HK*6500806

32.0

38.17

41.83

40

45

8

8

 

 

6HK*6501006

40.0

46.83

51.42

50

60

8

6

 

6HK*6500206

10.0

14.33

15.48

15

20

12

12

 

6HK*6500506

20.0

25.17

27.46

30

30

10

10

AHE24B3XH21

6HK*6500806

32.0

38.17

41.83

40

45

8

8

6HK*6501006

40.0

46.83

51.42

50

60

8

6

 

 

6HK16501306

52.0

59.83

65.79

60

70

6

4

 

6HK16501506

60.0

68.50

75.38

70

80

4

4

 

6HK*6500206

10.0

14.33

15.48

15

20

12

12

 

6HK*6500506

20.0

25.17

27.46

30

30

10

10

AHE30B3XH21

6HK*6500806

32.0

38.17

41.83

40

50

8

8

6HK*6501006

40.0

46.83

51.42

50

60

6

6

 

 

6HK16501306

52.0

59.83

65.79

60

70

6

4

 

6HK16501506

60.0

68.50

75.38

70

80

4

4

 

6HK*6500206

10.0

15.96

17.10

20

20

12

12

 

6HK*6500506

20.0

26.79

29.08

30

30

10

10

 

6HK*6500806

32.0

39.79

43.46

40

45

8

8

AHE36C3XH21

6HK*6501006

40.0

48.46

53.04

50

60

8

6

6HK16501306

52.0

61.46

67.42

70

70

6

4

 

 

6HK16501506

60.0

70.13

77.00

80

80

4

4

 

6HK16501806

72.0

83.13

91.38

90

100

3

3

 

6HK16502006

80.0

91.79

100.96

100

110

3

2

 

6HK*6500206

10.0

15.96

17.10

20

20

12

12

 

6HK*6500506

20.0

26.79

29.08

30

30

10

10

AHE42D3XH21

6HK*6500806

32.0

39.79

43.46

40

45

8

8

6HK*6501006

40.0

48.46

53.04

50

60

6

6

 

 

6HK16501306

52.0

61.46

67.42

70

70

6

4

 

6HK16501506

60.0

70.13

77.00

80

80

4

4

 

6HK*6500206

10.0

18.3

19.5

20

20

12

12

 

6HK*6500506

20.0

29.2

31.5

30

35

10

10

 

6HK*6500806

32.0

42.2

45.8

45

50

8

8

AHE48D3XH21

6HK*6501006

40.0

50.8

55.4

60

60

6

6

6HK16501306

52.0

63.8

69.8

70

70

4

4

 

 

6HK16501506

60.0

72.5

79.4

80

80

4

4

 

6HK16501806

72.0

85.5

93.8

90

100

3

3

 

6HK16502006

80.0

94.2

103.3

100

110

3

2

 

6HK*6500206

10.0

18.3

19.5

20

20

12

12

 

6HK*6500506

20.0

29.2

31.5

30

35

10

10

 

6HK*6500806

32.0

42.2

45.8

45

50

8

8

 

6HK*6501006

40.0

50.8

55.4

60

60

6

6

AHE60D3XH21

6HK16501306

52.0

63.8

69.8

70

70

4

4

 

6HK16501506

60.0

72.5

79.4

80

80

4

4

 

6HK16501806

72.0

85.5

93.8

90

100

3

3

 

6HK16502006

80.0

94.2

103.3

100

110

3

2

 

6HK16502506

100.0

115.8

127.3

120

130

1

1

1.O.C.P. = Over Current Protection device, must be HACR type Circuit Breaker or Time Delay fuse. * May be 0 (no Circuit Breaker) or 1 (with Circuit Breaker).